1-34
DNW-A220
DNW-A220P
SY-259/259A Board
Ref.No. Indicator name
Color
Description
Normal state
D201
SY1 STS1
Green
Blinks when the SYS1 CPU normally operates
Blinking
D202
SY1 STS2
Green
Lit when communication between SYS1 CPU and control
Lit
panel is under normal conditions
Unlit when the above communication is under abnormal
conditions
D203
MAINTE
Green
Lit during execution of the maintenance mode
Dark
D204
SY1 ERR
Red
Lit when the SYS1 CPU does not normally operate
Dark
Blinks when communication between SYS1 CPU and other
CPU (SYS2, or KY) is under abnormal conditions
SY-260 Board
Ref.No. Indicator name
Color
Description
Normal state
D201
SY2 STS1
Green
Blinks when the SYS2 CPU normally operates
Blinking
D202
SY2 STS2
Green
Lit when communication between SYS2 CPU and SV CPU is
Lit
under normal conditions
Unlit when the above communication is under abnormal
conditions
D203
SY2 STS3
Green
Lit when communication between SYS2 CPU and SYS1 CPU is Lit
under normal conditions
Unlit when the above communication is under abnormal
conditions
D204
SY2 ERR
Red
Lit when the SYS2 CPU does not normally operate.
Dark
Blinks when communication between SYS2 CPU and other
CPU (SYS1, or SV) is under abnormal conditions
1-10. Description on Internal Indicators