BVP-E30/E30P M-V1
5-13 (E)
R
M
G
B
C
Y
G
Y
L
R
M
G
C
Y
G
Y
L
B
(NTSC)
(PAL)
(Vectorscope)
Burst spot
75 %
TP501
TP502
TP503
TP1
E1
11 10
9
8
7
6
5
4
3
2
1
M
L
K
J
H
G
F
E
D
C
B
A
DPR-261 board (A side)
E501
TP800
E2
2.
VBS Level Adjustment
Menu setting
PAGE :
VA TRIMMING
ITEM :
TEST OUT
→
ENC
Adjustment Point
.
PAGE :
DPR TRIMMING
.
ITEM :
VBS Y LEVEL
Specifications : NTSC : A = 100
±
0.5 IRE
PAL :
A = 700
±
3 mV p-p
After the adjustment is completed, store the TRIM-
MING data.
(Press the MENU SELECT knob to execute.)
ITEM : STORE
Menu setting
PAGE :
VA TRIMMING
ITEM :
TEST OUT
→
ENC
Adjustment Point
.
PAGE :
DPR TRIMMING
.
ITEM :
VBS C LEVEL
Specifications : CROMA LEVEL
Each beam spot of vectorscope stays
inside the frame “
4
”.
A
A
(NTSC)
(PAL)
(Waveform monitor)
(Waveform monitor)
5-4-4. SC Frequency Adjustment
Equipment : Frequency counter
Test Point :
TP1 (GND : E1) /DPR-261
Preparations
n
Warm up the camera for about 15 minutes or more before
performing this adjustment.
.
Remove the left side panel. (Refer to Section 1-5.)
.
Disconnect the CCU connected to the camera, and
connect the AC-550/550CE to the camera.
.
When the cable is connected to GENLOCK IN connec-
tor of CA, disconnect the cable.
Adjustment Procedures
1.
Adjustment Point
.
MENU :
SERVICE
.
PAGE :
DPR TRIMMING
.
ITEM :
SC FREQ
Specifications :
36,000,000
±
10 Hz
2.
After the adjustment is completed, store the TRIM-
MING data.
(Press the MENU SELECT knob to execute.)