2-2 (E)
BVP-E30/E30P M-V1
*
1
*
1
Setscrews
(WP2
x
3)
Setscrew
(WP3
x
3)
CC filter knob
ND filter knob
Filter knob
BVP-E30/E30WS/E30WSP
BVP-E30P
Setscrews
(WP2
x
3)
6.
Remove the four screws, and remove the front panel.
7.
BVP-E30/E30WS/E30WSP
Remove the filter disk unit and the DR-536 board, and
install them into a new CCD unit. (Refer to Section 2-
1-3.)
8.
Reassemble the parts in the reverse order of removal.
n
After replacement, and adjust the position of the filter
knob referring to Section 2-1-2.
CCD unit
Front panel
M3
x
8
M3
x
8
SW3
SW3
5.
BVP-E30/E30WS/E30WSP
Loosen each two setscrews of the ND filter knob and
CC filter knob using an L shaped wrench (across flat
has 0.89 mm), and remove the knobs.
BVP-E30P
Loosen a setscrew of the filter knob using an L shaped
wrench (across flat has 1.5 mm), and remove the knob.