2-11 (E)
BVP-E30/E30P M-V1
MB-953 board
TEST OUT connector
CN-2210 board
Cap
CN17
Precision
P2.6
x
5
2-7. Replacing the LENS Connector
1.
Remove the V shoe bracket. (Refer to Section 2-5.)
2.
Disconnect the harness from the connector CN14 of
the MB-953 board.
3.
Remove the two screws, and the front switch panel.
4.
Remove the two screws, and remove the LENS
connector.
5.
Desolder the LENS connector, and replace it.
6.
Reassemble the parts in the reverse order of removal.
2-8. Replacing the TEST OUT Connector
1.
Remove the V shoe bracket. (Refer to Section 2-5.)
2.
Remove the left side panel. (Refer to Section 1-5.)
3.
Remove the DPR-261 board. (Refer to Section 2-1.)
4.
Disconnect the harness from the connector CN17 of
the MB-953 board.
5.
Pull out the cap.
6.
Remove the screw, and remove the TEST OUT
connector.
7.
Desolder the TEST OUT connector, and replace it.
8.
Reassemble the parts in the reverse order of removal.
MB-953 board
Front switch panel
LENS connector
CN14
Precision
P2.6
x
5
Precision
P2.6
x
5