1-14 (E)
BVP-E30/E30P M-V1
<DIAGNOSIS>
ROM:V1.00
CAMERA:UC CA-570
OHB:-- MD:--
VA :-- AU:--
DPR:-- TR:--
IF :--
AT :--
HUR:99999H
CCU :--
1
2
3
4
8
5
7
6
CA-570 CA-550
MD:-- MD:--
AU:-- AU:--
TR:-- TR:--
CA-530 CA-950
VSE:-- DA :--
DVP:-- IF :--
DC :-- AU :--
SDI:--
DPR:--
TX :--
1-8. Diagnosis
The unit is provided with the diagnosis function which can be used for the self-diagnosis of each plug-in
board and the OHB, and is displayed in the OPERATION menu.
Operation
Display the “DIAGNOSIS” page of the OPERATION menu referring to Section 3-1.
Display
Description on display
Marks
Board/Block
Criteria for judging
1
OHB (CCD UNIT)
Communication error with IC8/PA-272 board
2
VA-226
Communication error with IC701 or defect of sub-regulator circuit operation inside the
board.
3
DPR-261
Communication error with IC507 or defect of sub-regulator circuit operation inside the
board.
4
IF-969
Communication error with IC307 or defect of sub-regulator circuit operation inside the
board.
5
AT-148
Low capacity of BT1
6
HUR
Indicates the power-on time of the camera. (The display stops in 99999 when the
power-on time exceeds 99999H.)
7
CCU/RM
*
The serial data is correctly received from the CCU or RM connected to the unit.
(“
__
” is displayed during a normal operation.)
*
When neither CCU nor RM is connected, “RM: NC” is displays.
About mark
8
CA, is as described below according to the type of CA connected to the camera.
Refer to the maintenance manual supplied with the camera adaptor.