1-1 (E)
BVP-E30/E30P M-V1
Section 1
Service Overview
1-1. Note on Service
1-1-1. Confirming the ROM Version
When connecting any of the peripheral equipment in the
following list to this unit, be sure to check that the version
of ROM of each peripheral device to be connected.
If ROM version is lower than the specified below, be sure
to perform ROM replacement.
Model
Ref No.
ROM version
MSU-700A
IC5, IC6/CPU-293 board
Ver. 1.20 and
higher
MSU-750
IC5, IC6/CPU-286 board
Ver. 1.20 and
higher
CCU-700A
IC1004/AT-88 board
Ver. 2.90 and
higher
CCU-550A
IC133/AT-111 board
Ver. 3.00 and
higher
CNU-700
IC4, IC5/AT-89 or
Ver. 3.30 and
AT-89A board
higher
CNU-500
IC4, IC5/AT-100 board
Ver. 2.90 and
higher
RCP-720 Series
IC10/MPU-79 board
Ver. 2.80 and
RCP-730 Series
higher
RCP-740 Series
RM-B750 Series
Ver. 1.01 and
higher
RCP-750 Series
Ver. 1.01 and
higher
RM-B150
IC4/CPU-266 board
Ver. 1.20 and
higher
1-1-2. Compatibility of File Data
The file data does not have compatibility with other
cameras.
When using the file data stored in the memory stick or the
IC memory card (for MSU), make sure that the file data for
BVP-E10 series or BVP-E30 series are stored.
(For details on the file system, refer to Section 4.)
1-1-3. Error Messages Displayed when
Memory Stick is Used
Describes the error messages displayed when the data is
stored or read using a memory stick in the table below.
Error message
Description
NO MEMORY STICK
No memory stick is inserted.
FORMAT ERROR
The memory stick is not formatted.
OTHER MODEL’S FILE
The memory stick contains data
cannot be read by this unit.
FILE NOT FOUND
No data is stored in the memory
stick.
FILE ERROR
Circuit or memory stick fault and/or
the data in the memory stick fault.
1-1-4. Note on PA-272/273/274 Boards
The PA-272/273/274 boards cannot be replaced as the
mounted board level. If the component part mounted on
the board cannot be replaced, replace with the whole CCD
unit.