BVP-E30/E30P M-V1
1-3. Connection Connector
Connection made with the connector panels during installation or service, should be made with the
connector specified in the following list, or equivalent parts.
Connector Name
Connection Connectors
TEST OUT (BNC)
1-569-370-12 Plug, BNC
MIC IN (3P FEMALE)
1-508-084-00 XLR, 3P Male or ITT Cannon XLR-3-12C equivalent
1-4. Function of Internal Switches
Ref. No.
Designation
Description
Factory setting
S1
MIC
+
48 V
MIC POWER
+
48 V ON/OFF switch
ON
Set to OFF when using the microphone of the internal
batteries type.
S1
14
13
12
11
10
9
8
7
6
5
4
3
2
1
G
F
E
D
C
B
A
MB-953 board (B side)
ON