BVP-E30/E30P M-V1
5-7 (E)
TP1
TP2
TP3
E1
A
B
C
D
E
F
G
1
2
3
4
5
6
7
8
9
10
11
12
VA-226 board (A side)
A
1H
(Oscilloscope)
3.
Flare Offset B Adjustment
Test Point :
TP3 (GND : E1)
Adjustment Point
.
ITEM :
FLR OFFSET [B]
Specifications : A = 0
±
10 mV
4.
Store the TRIMMING data.
(Press the MENU SELECT knob to execute.)
ITEM : STORE
5-2. VA-226 Board Adjustment
Perform the adjustments from Sections 5-2-1 to 5-2-3 in
order.
5-2-1. Black Balance Adjustment
Perform automatic adjustment of black balance as follows.
(1) When MSU is not used, set the AUTO W/B BAL
switch on the front of the camera to the BLK side.
(2) When MSU is used, set the BLACK button on MSU to
ON (lit).
5-2-2. Flare Offset Adjustment
Equipment :
Oscilloscope
Board extension : VA-226 board
Preparations
.
Lens Iris
→
CLOSE
.
Menu settings
MENU : SERVICE
PAGE :
VA TRIMMING
Adjustment Procedures
1.
Flare Offset R Adjustment
Test Point :
TP2 (GND : E1)
Adjustment Point
.
MENU :
SERVICE
.
PAGE :
VA TRIMMING
.
ITEM :
FLR OFFSET [R]
Specifications : A = 0
±
10 mV
2.
Flare Offset G Adjustment
Test Point :
TP1 (GND : E1)
Adjustment Point
.
ITEM :
FLR OFFSET [G]
Specifications : A = 0
±
10 mV