![SNR S2940-8G-v2 Configuration Manual Download Page 92](http://html1.mh-extra.com/html/snr/s2940-8g-v2/s2940-8g-v2_configuration-manual_1310630092.webp)
SNR S2940-8G-v2 Switch Configuration Guide
DDM Configuration
Switch(config)#show transceiver threshold-violation interface ethernet 1/21-22
Ethernet 1/21 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-violation doesn't exist.
Ethernet 1/22 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-violation doesn't exist.
Step 2:
Enable the transceiver monitoring of ethernet 1/21.
Switch(config)#interface ethernet 1/21
Switch(config-if-ethernet1/21)#transceiver-monitoring enable
Step 3:
Show the transceiver monitoring of the fiber module. In the following configuration,
ethernet 21 enabled the transceiver monitoring, the last threshold-violation time is Jan 02 11:00:50
2011, the detailed DDM information exceeding the threshold is also shown.
Switch(config-if-ethernet1/21)#quit
Switch(config)#show transceiver threshold-violation interface ethernet 1/21-22
Ethernet 1/21 transceiver threshold-violation information:
Transceiver monitor is enabled. Monitor interval is set to 30 minutes.
The current time is Jan 02 12:30:50 2011.
The last threshold-violation time is Jan 02 11:00:50 2011.
Brief alarm information:
RX loss of signal
RX power low
Detail diagnostic and threshold information:
Diagnostic
Threshold
Realtime
High Alarm
Low Alarm
High Warn
Low Warn
---------
----------
-----------
---------
---------
Temperature
33
70
0
70
0
Voltage(V)
7.31
10.00
0.00
5.00
0.00
Bias current(mA)
3.11
10.30
0.00
5.00
0.00
RX Power(dBM)
-30.54(A-) 9.00
-25.00(-34)
9.00
-25.00
TX Power(dBM)
-1.01
9.00
-12.05
9.00
-10.00
Ethernet 1/22 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-violation doesn't exist.
12.4
DDM Troubleshooting
If problems occur when configuring DDM, please check whether the problem is caused by the
following reasons:
• Ensure that the transceiver of the fiber module has been inserted fast on the port, or else
DDM configuration will not be shown.
92
Summary of Contents for S2940-8G-v2
Page 11: ...SNR S2940 8G v2 Switch Configuration Guide Part I Basic Management Configuration 11...
Page 46: ...SNR S2940 8G v2 Switch Configuration Guide Part II Port Configuration 46...
Page 123: ...SNR S2940 8G v2 Switch Configuration Guide Part III VLAN and MAC Table Configuration 123...
Page 164: ...SNR S2940 8G v2 Switch Configuration Guide Part IV MSTP Configuration 164...
Page 198: ...SNR S2940 8G v2 Switch Configuration Guide Part VI L3 Forward and ARP Configuration 198...
Page 218: ...SNR S2940 8G v2 Switch Configuration Guide Part VII DHCP Configuration 218...
Page 257: ...SNR S2940 8G v2 Switch Configuration Guide Part VIII Multicast Protocol 257...
Page 278: ...SNR S2940 8G v2 Switch Configuration Guide Part IX Security Function Configuration 278...
Page 376: ...SNR S2940 8G v2 Switch Configuration Guide Part X Reliability Configuration 376...
Page 395: ...SNR S2940 8G v2 Switch Configuration Guide Part XI Flow Monitor Configuration 395...
Page 403: ...SNR S2940 8G v2 Switch Configuration Guide Part XII Network Time Management Configuration 403...
Page 411: ...SNR S2940 8G v2 Switch Configuration Guide Part XIII Debugging and Diagnosis 411...