![SNR S2940-8G-v2 Configuration Manual Download Page 111](http://html1.mh-extra.com/html/snr/s2940-8g-v2/s2940-8g-v2_configuration-manual_1310630111.webp)
SNR S2940-8G-v2 Switch Configuration Guide
CFM-OAM Configuration
7. Configure RMEP
Command
Explanation
MA Configuration Mode
continuity-check receive rmep
<mep-id> [active time < time >]
no
continuity-check
receive
rmep <mep-id>
Open CCM message receiving function and build up rmep
in MA. If the mepid in an MA has been configured as MEP,
it cannot be configured as RMEP. No command deletes the
configured RMEP.
8. Create MIP (selectable)
Command
Explanation
MD Configuration Mode; MA Configuration Mode
mip auto-create [ lower-mep-
only | none ]
no mip auto-create
Configure the automatic MIP in the maintenance collection's
domain. As default, there is no rule of configuring the mid
point; and it does not carry the sender-id. No command
deletes the MIP.
Global Mode
ethernet cfm mip auto-create
level < level-id > vlan < WORD
> [lower-mep-only] [sender-id
chassis]
no mip auto-create
Build up the MIP configuration on the layer that does not
relate to MA. As default, there is no rule of configuring the
mid point; and it does not carry the sender-id. No command
deletes the MIP.
9. Enable the failure confirmation function (selectable)
Command
Explanation
Global mode
ethernet cfm alarm { delay <
mseconds > | notification { all
| error-xcon | mac-remote-error-
xcon | none | remote-error-xcon
| xcon } | reset < mseconds > }
no ethernet cfm alarm { delay
| notification { all | error-xcon |
mac-remote-error-xcon | none |
remote-error-xcon | xcon } | reset
}
Enable the function of error alarm. No command recovers
to be default.
ethernet cfm logging
no ethernet cfm logging
Open the log record function. If alarm is occur, it means that
has already recorded or inform out of order. No command
disables this function.
ethernet cfm snmp-server en-
able traps
no ethernet cfm snmp-server en-
able traps
Having the snmp notification during the alarm. If the set up is
success, it will have the snmp notification during the alarm.
No command disables this function.
111
Summary of Contents for S2940-8G-v2
Page 11: ...SNR S2940 8G v2 Switch Configuration Guide Part I Basic Management Configuration 11...
Page 46: ...SNR S2940 8G v2 Switch Configuration Guide Part II Port Configuration 46...
Page 123: ...SNR S2940 8G v2 Switch Configuration Guide Part III VLAN and MAC Table Configuration 123...
Page 164: ...SNR S2940 8G v2 Switch Configuration Guide Part IV MSTP Configuration 164...
Page 198: ...SNR S2940 8G v2 Switch Configuration Guide Part VI L3 Forward and ARP Configuration 198...
Page 218: ...SNR S2940 8G v2 Switch Configuration Guide Part VII DHCP Configuration 218...
Page 257: ...SNR S2940 8G v2 Switch Configuration Guide Part VIII Multicast Protocol 257...
Page 278: ...SNR S2940 8G v2 Switch Configuration Guide Part IX Security Function Configuration 278...
Page 376: ...SNR S2940 8G v2 Switch Configuration Guide Part X Reliability Configuration 376...
Page 395: ...SNR S2940 8G v2 Switch Configuration Guide Part XI Flow Monitor Configuration 395...
Page 403: ...SNR S2940 8G v2 Switch Configuration Guide Part XII Network Time Management Configuration 403...
Page 411: ...SNR S2940 8G v2 Switch Configuration Guide Part XIII Debugging and Diagnosis 411...