![SNR S2940-8G-v2 Configuration Manual Download Page 91](http://html1.mh-extra.com/html/snr/s2940-8g-v2/s2940-8g-v2_configuration-manual_1310630091.webp)
SNR S2940-8G-v2 Switch Configuration Guide
DDM Configuration
RX loss of signal
Voltage high
RX power low
Detail diagnostic and threshold information:
Diagnostic
Threshold
Realtime
High Alarm
Low Alarm
High Warn
Low Warn
----------
----------
---------
---------
---------
Temperature
33
70
0
70
0
Voltage(V)
7.31(A+)
5.00
0.00
5.00
0.00
Bias current(mA)
6.11(W+)
10.30
0.00
5.00
0.00
RX Power(dBM)
-30.54(A-)
9.00
-25.00
9.00
-25.00
TX Power(dBM)
-13.01
9.00
-25.00
9.00
-25.00
Step 2:
Configure the tx-power threshold of the fiber module, the low-warning threshold is -12,
the low-alarm threshold is -10.00.
Switch#config
Switch(config)#interface ethernet 1/21
Switch(config-if-ethernet1/21)#transceiver threshold tx-power low-warning -12
Switch(config-if-ethernet1/21)#transceiver threshold tx-power low-alarm -10.00
Step 3:
Show the detailed DDM information of the fiber module. The alarm uses the threshold
configured by the user, the threshold configured by the manufacturer is labeled with the bracket.
There is the alarm with
A-
due to -13.01 is less than -12.00.
Switch#show transceiver interface ethernet 1/21 detail
Ethernet 1/21 transceiver detail information:
Base information:
Brief alarm information:
RX loss of signal
Voltage high
RX power low
TX power low
Detail diagnostic and threshold information:
Diagnostic
Threshold
Realtime
High Alarm
Low Alarm
High Warn
Low Warn
----------
----------
-------------
---------
---------
Temperature
33
70
0
70
0
Voltage(V)
7.31(A+)
5.00
0.00
5.00
0.00
Bias current(mA)
6.11(W+)
10.30
0.00
5.00
0.00
RX Power(dBM)
-30.54(A-)
9.00
-25.00
9.00
-25.00
TX Power(dBM)
-13.01(A-)
9.00
-12.00(-25.00) 9.00
-10.00(-25.00)
Example 3:
Ethernet 1/21 is inserted the fiber module with DDM. Enable the transceiver monitoring of the
port after showing the transceiver monitoring of the fiber module.
Step 1:
Show the transceiver monitoring of the fiber module. Both ethernet 1/21 and ethernet
1/22 do not enable the transceiver monitoring, its interval is set to 30 minutes.
91
Summary of Contents for S2940-8G-v2
Page 11: ...SNR S2940 8G v2 Switch Configuration Guide Part I Basic Management Configuration 11...
Page 46: ...SNR S2940 8G v2 Switch Configuration Guide Part II Port Configuration 46...
Page 123: ...SNR S2940 8G v2 Switch Configuration Guide Part III VLAN and MAC Table Configuration 123...
Page 164: ...SNR S2940 8G v2 Switch Configuration Guide Part IV MSTP Configuration 164...
Page 198: ...SNR S2940 8G v2 Switch Configuration Guide Part VI L3 Forward and ARP Configuration 198...
Page 218: ...SNR S2940 8G v2 Switch Configuration Guide Part VII DHCP Configuration 218...
Page 257: ...SNR S2940 8G v2 Switch Configuration Guide Part VIII Multicast Protocol 257...
Page 278: ...SNR S2940 8G v2 Switch Configuration Guide Part IX Security Function Configuration 278...
Page 376: ...SNR S2940 8G v2 Switch Configuration Guide Part X Reliability Configuration 376...
Page 395: ...SNR S2940 8G v2 Switch Configuration Guide Part XI Flow Monitor Configuration 395...
Page 403: ...SNR S2940 8G v2 Switch Configuration Guide Part XII Network Time Management Configuration 403...
Page 411: ...SNR S2940 8G v2 Switch Configuration Guide Part XIII Debugging and Diagnosis 411...