![SNR S2940-8G-v2 Configuration Manual Download Page 121](http://html1.mh-extra.com/html/snr/s2940-8g-v2/s2940-8g-v2_configuration-manual_1310630121.webp)
SNR S2940-8G-v2 Switch Configuration Guide
CFM-OAM Configuration
– MA name:
1
∼
43 characters straing.It can be formed by letter, number, underline and
the first and the last character cannot be underline. The sum of MA and the domain
name cannot excess than 44 characters.
• In the same level, a primary vlan can only be related by one MA.
• MD level, MA related pvlan and UP/DOWN attribute cannot be changed after develop
• Need to build up the MEP ID before configure the MEP and RMEP
• MEP ID in one MA , after configured as MEP, the nit cannot be change to configure RMEP
• he DOWN attribute of MA in one facility can only allow existing one MEP; one UP attribute
MA can allow to exist of several of MEP, but it cannot allow to configure several identical MA
MEP to the same port.
2. Cannot build up the CC connection
• Through the show ethernet cfm to checking, ensure both port's level, MD name, MA name,
MA related pvlan are the same.
• Ensure the configuration of RMEP of this port is same with the configured MEP ID at the
other port.
• Ensure this port and the other port opened the CC sending and checking function
• Ensure the CCM sending period is the same for two port
• Configured the down mep on the port, then mep will receive the message from this port. If
it configured the up mep, then the mep will receive the messages from others ports. Please
ensure that the up mep configuration is on the non-receiving port.
• The port that is blocking by STP protocol cannot receiving, sending, replying the CFM mes-
sages. If it is configured as MEP, then even if that port was blocked by the STP protocol,
it can still sending and receiving CCM messages. Only the second layer Ethernet port can
support the CFM function.
• MEP and MIP can configure on the port channel, but at the same time, port channel config-
ured MEP and MIP will ineffective on the members. If you want to increase the CFM MEP
and MIP port to port channel, then that port's MEP and MIP will ineffective as well. If you
want to recover the MEP and MIP on the port, then need to delete the port-channel from this
port.
3. Cannot create the MIP point
• Ensure the develop rules of MIP is correct
– Default rules:
If there is not a higher level of MEP on the port, and at the same time,
lower level of MIP does not exist, then it will build up MIP on particular port at this level.
– Explicit rules:
If there is not a higher level of MEP on the port, but at the same time,
lower level of maintenance mid-point does not exist, then it will build up the mid-point
depends on whether there is a maintenance base point on lower level.
121
Summary of Contents for S2940-8G-v2
Page 11: ...SNR S2940 8G v2 Switch Configuration Guide Part I Basic Management Configuration 11...
Page 46: ...SNR S2940 8G v2 Switch Configuration Guide Part II Port Configuration 46...
Page 123: ...SNR S2940 8G v2 Switch Configuration Guide Part III VLAN and MAC Table Configuration 123...
Page 164: ...SNR S2940 8G v2 Switch Configuration Guide Part IV MSTP Configuration 164...
Page 198: ...SNR S2940 8G v2 Switch Configuration Guide Part VI L3 Forward and ARP Configuration 198...
Page 218: ...SNR S2940 8G v2 Switch Configuration Guide Part VII DHCP Configuration 218...
Page 257: ...SNR S2940 8G v2 Switch Configuration Guide Part VIII Multicast Protocol 257...
Page 278: ...SNR S2940 8G v2 Switch Configuration Guide Part IX Security Function Configuration 278...
Page 376: ...SNR S2940 8G v2 Switch Configuration Guide Part X Reliability Configuration 376...
Page 395: ...SNR S2940 8G v2 Switch Configuration Guide Part XI Flow Monitor Configuration 395...
Page 403: ...SNR S2940 8G v2 Switch Configuration Guide Part XII Network Time Management Configuration 403...
Page 411: ...SNR S2940 8G v2 Switch Configuration Guide Part XIII Debugging and Diagnosis 411...