- 122 -
951-170-218-EN
Version 06
EN
12. Malfunctions, causes, and remedies
12.3
Error with the use of MQL systems with bypass control
Malfunctions, causes, and remedies, Table 16
Malfunction
Cause
Remedy
Insufficient amount of
aerosol at tool
o Inlet air pressure is fluctuating
• Check inlet pressure and correct if necessary
o Inlet air pressure too low
• Check inlet air pressure and correct if necessary (max.
10 bar)
o Bypass restrictor on bypass valve contaminated
• Blow out the bypass restrictor; to do so, close the ball valve
upstream of the spindle and execute lubrication program
No. 3
o Opening on bypass restrictor unsuitable
• Test bypass restrictor with different opening or record op-
erating parameters and contact SKF Service
o Leakage in bypass system (Y-distributor on bypass re-
strictor of ball valve)
• Identify and resolve leak
Bypass valve does not
cycle during machining
process
o Incorrect program number configured
• Use program number 50
o Unsuitable ratio between cooling duct diameter and by-
pass restrictor diameter
• Record operating parameters and contact SKF Service