11. Maintenance
- 115 -
951-170-218-EN
Version 06
CAUTION
System pressure
The refilling reservoir must be
depressurized before refilling with
lubricant.
• Activate lubrication program No. 3
(Chapter 8.2.3.6).
• Disconnect the compressed air line from
the system and push the coupling (
2
)
downwards
or:
Move the slider (
3
) on the main com-
pressed air valve downwards.
• Open the aerosol outlets (
4
) (possibly via
ball valves) to ensure free release of the
reservoir pressure.
• Wait until the pressure has been released
via the aerosol outlets (
4
).
Check whether the pressure has been
completely released by briely actuating
the safety valve (
5
).
CAUTION
Wear safety goggles and a facial
mask
Aerosol may escape during subse-
quent actuation of the safety valve.
• Briely actuate the safety valve (
5
) using
the key ring.
If you have any questions, please contact
our sales and service centers or our repre-
sentatives abroad.
A list with current addresses is available on
the Internet at:
www.skf.com/lubrication
11.2 Reilling lubricant in systems with manual lubricant reill
See Figure 54