8
EN
8. Communication with machine control unit
- 105 -
951-170-218-EN
Version 06
Lubrication programs, Table 14,
(1 of 2)
Program
No.
Output byte 1
Air volume
flow
Lubricant volume
flow
1
)
[ml/h]
Cooling duct diameter
of tool [mm]
7
6
5
4
3
2
1
0
1 duct
2 ducts
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
1
25%
0
2
0
0
0
0
0
0
1
0
50%
0
3
0
0
0
0
0
0
1
1
100%
0
4
0
0
0
0
0
1
0
0
Automatic
control
5
1x1
2x0.7
5
0
0
0
0
0
1
0
1
7
6
0
0
0
0
0
1
1
0
10
1x1.5
2x1.1
7
0
0
0
0
0
1
1
1
15
8
0
0
0
0
1
0
0
0
20
1x2
2x1.4
9
0
0
0
0
1
0
0
1
25
10
0
0
0
0
1
0
1
0
30
11
0
0
0
0
1
0
1
1
35
12
0
0
0
0
1
1
0
0
40
1x2.5
2x1.8
13
0
0
0
0
1
1
0
1
45
1x3
2x2.1
14
0
0
0
0
1
1
1
0
50
15
0
0
0
0
1
1
1
1
55
1x3.5
2x2.5
16
0
0
0
1
0
0
0
0
60
17
0
0
0
1
0
0
0
1
70
1x4
2x2.8
18
0
0
0
1
0
0
1
0
85
19
0
0
0
1
0
0
1
1
100
20
0
0
0
1
0
1
0
0
120
1x5
2x3.5
21
0
0
0
1
0
1
0
1
140
22
0
0
0
1
0
1
1
0
160
23
0
0
0
1
0
1
1
1
180
24
0
0
0
1
1
0
0
0
200