7. Setup and fieldbus configuration on MQL system
- 86 -
951-170-218-EN
Version 06
7.1.1 Setting options via DIP switches
Setting options for DIP switches, Table 7
DIP switch
Function
Setting
AM1000 aerosol monitor
DIP 8
ON
Present (connected)
OFF
Not present (not connected)
Process image
DIP 7
ON
With analog value transmission
OFF
Without analog value transmission
Minimal quantity lubrication
system
DIP 6
ON
UFD20-02X
OFF
UFD10-02X
Not assigned
DIP 5
Communication connection
DIP 4
ON
Enabled
OFF
Disabled
Control of the automatic refill
device
DIP 2 / DIP 3
0N
0N
Manual reset timeout
ON
OFF
Automatic refilling if below "minimum fill level" (fill level
switch, position S2)
OFF
ON
Automatic refilling if below "reservoir full" (fill level switch,
position S3)
OFF OFF
No automatic refilling (control via PROFIBUS, output byte 0,
bit 0 possible)
Control of additional valve
(see Chapter 7.1.1.1 for func-
tional options)
DIP 1
0N
Via PROFIBUS
OFF
Automatic by control unit
4
1
3
2
ON
5 6 7 8