Model:

IHS22-E4

Owner’s Manual

Powered by 

Summary of Contents for IHS22-E4

Page 1: ...Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Model IHS22 E4 Owner s...

Page 2: ...d VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV equipment An increasing number of calls to VIQUA Technical Suppo...

Page 3: ...t Interrupter GFCI This symbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock...

Page 4: ...at least 10 of copper pipe on the outlet of your UV chamber Hg EXPOSURE The UV lamp contains mercury If the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and...

Page 5: ...230V IHS22 E4 2 260013 Australian IHS22 E4 2A 260012 UK IHS22 E4 2B 7 Controller includes Controller mounting bracket Lamp connector 650733R 001 Used on all systems 8 Controller mounting bracket 9 La...

Page 6: ...iqua website WWW VIQUA COM LCD 2 1 Dimensions and Layout Figure 2 Model IHS22 E4 Controller Components Figure 3 System Dimension and Layout 100 240 VAC 50 60Hz 1 2A SERIAL 000001 PART IHS22 E4 REPLACE...

Page 7: ...ystem Provides filtration and UV 6 Controller Powers and controls the UV lamp and other devices Provides human interface displaying information and allowing control inputs such as muting the audible a...

Page 8: ...ws CAUTION The sump housings will be heavy 5 Ensure quartz sleeve is properly centered in the chamber 6 2 1 Place sleeve bolt onto the quartz sleeve carefully push down and hand tighten onto chamber 7...

Page 9: ...d pour 2 cups of household bleach solution into the sump housings Note DO NOT use Hydrogen Peroxide 7 1 1 2 2 Reinstall the housings 8 0 30 15 45 30 mins Open all faucets and turn on the cold water su...

Page 10: ...Buttons and Display Feature Description Function A Status Screen Displays the following Lamp life days Product information Product support UV level status Active alarms B Pushbutton 1 Scroll Mute 24Hr...

Page 11: ...elect to enter the model preferred This ensures the correct replacement parts are displayed in the Info screen Product Registration Reminds USER to register their product for product updates and lamp...

Page 12: ...ESET screen Lamp Replacement RESET Press and hold button for 5 seconds until you here an audible beep Your Lamp Life Days is now reset to 365 days Lamp life 30 Days Remaining Status Info Support Lamp...

Page 13: ...Lamp Failure Scroll V V 1 UV Lamp Ignition Fault UV Lamp Run Fault 2 Unplug UV system from main power supply 3 Check for secure lamp connection 4 Restore power to UV system Lamp Failure Scroll V V 5 I...

Page 14: ...or contact information select support screen Status Info Support Scroll V V Controller Failure Mute 1 Unplug UV system from main power supply 2 Allow 30 seconds for unit to fully power down 3 Restore...

Page 15: ...display will be blank and a solid audible tone will sound Replace Controller Sensor Signal 1 Sensor signal is outside of proper operating parameters 2 Replace UV sensor Failure 3 See Info screen for r...

Page 16: ...E4 650718 SYS E4 PROFESSIONAL 230VAC E4 660040 R SYS E4 V NSF Class B 120VAC E4 V 650683 SYS E4 PROFESSIONAL 120VAC E4 650719 SYS E4 PROFESSIONAL 230VAC E4 660043 R SYS E4 V NSF Class B 120VAC E4 V 6...

Page 17: ...Failure 3 Lamp Failure 4 UV Sensor Failure Figure 6 Dry Contact Connections Dry Contact Connection Logic Chart Output Connection UV System Running Normally No Major Alarms UV System Is In a Major Ala...

Page 18: ...l this hot water has been purged from your chamber Do not allow water to contact your skin during this time To eliminate this condition a temperature management valve can be installed at the outlet of...

Page 19: ...contaminated after the UV system it is necessary to complete the cleaning procedure Refer to Section 3 2 1 2 1 Unscrew the sleeve bolt and carefully remove it from the top of the chamber Note Sleeve...

Page 20: ...aker repeatedly trips Connection between lamp and lamp plug is wet Clean and dry lamp pins and lamp plug check unit for leaks or condensation Short circuit in the electrical assembly Replace controlle...

Page 21: ...talled Remove the sump wipe the O ring and threads clean ensure the O ring is fitted properly then reinstall Filter cartridge not centered Remove sump check for cartridge damage re assemble ensuring c...

Page 22: ...ardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective...