SAFETY ALERT SYMBOLS 

 

Read and follow all safety information carefully.  The signal words used in this manual are 

selected as shown below and based on an assessment of the degree of potential injury or 

damage (severe or minor) and the occurrence of injury (definitely occurs or has the potential to 

occur) when the warning is ignored: 

 

 DANGER!   

Indicates a situation which, when not avoided, results in death or severe injury.   

 

 WARNING!   

Indicates a situation which, when not avoided, has the potential to result in death or 

severe injury; and/or severe property damage.  

  

 

 CAUTION!   

Indicates a situation which, when not avoided, results or has the potential to result in 

minor injury; and/or minor property damage. 

 

 

SAFETY PRECAUTIONS 

 

Basic safety precautions should be followed, including the following: 

Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are 

met when installing 

Waterlogic

 Equipment.   Only qualified service technicians should attempt 

installation and service of 

Waterlogic

 Equipment.  Always read the entire operating instructions 

before using the appliance and save these instructions for future use. 

 

DANGER!  

This product can cause death or severe injury if incorrectly operated, installed or 

maintained. 

The installation, maintenance, sanitizing and any repair must be performed by 

qualified persons trained by Waterlogic International or their approved distributors only.  Do 

not remove any panel or cover to protect against electrical shock and exposure to UV 

radiation.   

 

DANGER! 

ELECTRICAL SHOCK HAZARD

.  

Always use a dedicated and properly grounded 

outlet.  Unit should be protected by ground-fault circuit interrupter (GFCI) or residual current 

device (RCD) having a rated residual operating current not exceeding 30mA.  Use only 

Waterlogic supplied power cord. Never use extension cords or power strips to connect unit. 

Do not use if the power supply cord is damaged. Always unplug from power supply prior to 

servicing. 

 

WARNING!

  

AUTHORIZED USE ONLY.  

This appliance is to be used for its intended purpose as 

described in this manual. Untrained individuals who use this manual assume the risk of any 

resulting property damage or personal injury.  This appliance can’t be used by children and 

persons with reduced physical, sensory, or mental capabilities or lack of experience.   

 

     WARNING! 

UV-C EMITTER (UV LAMP)

.  

This appliance contains a UV-C emitter (UV Lamp). 

UV-C radiation may, even in small doses, cause harm to the eyes and skin. Unintended use or 

damage to the housing may result in the escape of dangerous UV-C radiation. Never operate 

the UV-C emitter if damaged or removed from enclosure. Do not touch or look directly into 

the faucet. 

Summary of Contents for WL3 IT

Page 1: ...erated installed or maintained The installation maintenance sanitizing and any repair must be performed by qualified persons trained by Waterlogic International or their approved distributors only Do not remove any panel or cover to protect against electrical shock and exposure to UV radiation DANGER ELECTRICAL SHOCK HAZARD Always use a dedicated and properly grounded outlet Unit should be protect...

Page 2: ...s sanitize before use to eliminate any potential microbiological contaminates CAUTION INDOOR USE ONLY Intended for Household Use Never expose to direct sunlight heat sources or ambient air temperature above 37 C 100 F or below 2 C 35 F Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrige...

Page 3: ...es the Hot Water selection to be double tapped until the Red Light flashes and then pressed and held to dispense Hot Water Note there is a 2 second delay until hot water begins flowing It will default back to the Cold selection after 3 seconds of inactivity to prevent accidental dispensing of Hot Water In Tank UV Purification Industry leading In Tank UV Purification prevents the growth of biofilm ...

Page 4: ...ed breakthrough The Firewall the most comprehensive UV purification system for point of use water treatment systems ever developed The Waterlogic Firewall component has been tested and certified by the Water Quality Association WQA to NSF ANSI 55 Class A Ultraviolet Microbiological Water Treatment Systems This Class A system conforms to NSF ANSI 55 for the disinfection of microbiologically contami...

Page 5: ... This filter must remain installed in the WL350 to maintain these certifications Energy Star Certified The WL3 FX Water Treatment System has been tested and certified to the Energy Star a US Environmental Protection Agency EPA program that helps our customers save money and protect our climate through superior energy efficiency Waterlogic is certified to ISO 9001 2015 Quality Management Systems ce...

Page 6: ...et Point 5 C 41 F Adjustable 1 1 12 2 C 34 54 F Cold Tank Size Tower 4 Liters 1 1 Gallons Counter Top 2 Liters 53 Gallons Hot Water Temperature 87 C 189 F Factory Set Point 92 C 198 F Extra Hot Factory Set Point Hot Water Manual Reset Overload 105 C 221 F Hot Tank Size 1 5 Liters 40 Gallons Recommended Service Pressure 40 60 psi 275 414 kPa Use Pressure Regulator Maximum Service Pressure 100 psi 6...

Page 7: ...kg 52 9 pounds 27 kg 59 5 pounds Counter Top is 17 75 in tall and may not fit between countertops and cabinets Check installation to ensure adequate clearance ELECTRICAL SPECIFICATIONS ELECTRICAL SUPPLY 120V 60Hz 1PH 15 Amp Service COMPONENT POWER approximate AMP DRAW approximate Heater 504 4 2 Amps Compressor 216 1 8 Amps UV Lamp System 18 0 15 Amps WL3 IT TOTAL 738 6 15 Amps 15 2 17 5 17 8 15 2 ...

Page 8: ...tra Hot Water Press and Hold the Hot Dispense Icon for 10 seconds to activate the heater LED will flash slowly until water is Extra Hot When the LED stops flashing repeat the dispense operation for Hot Water For Ambient Water Press and Hold the Ambient Dispense Icon NOTE If the user initiates extra hot but then loses patience and does not want to wait any longer then they can Press twice and Hold ...

Page 9: ...c for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting installation and maintenance data After you submit a Return Authorization form and supporting documentation Waterlogic will determine whether a reasonably apparent defect in materials or workmanship covered by this l...

Reviews: