background image

 

WL3 IT

 Manual 

                                                      Page 7 - Revision: 6-8-2021 

CERTIFICATIONS

 

 

WL3 FX

 

Water Treatment

 

Systems

 have been tested and certified to rigorous NSF and UL 

Standards.  We believe that performance testing and certifications validate 

Waterlogic 

as a 

world-leader in water treatment systems.     

Waterlogic WL3 FX 

Component Certifications Include: 

UL399 – Certified Drinking Water Cooler 

Intertek Labs (ETL) Certified the 

WL3 FX

 

Water

 

Treatment System

 to ANSI/UL 399 

Standard for Drinking Water Coolers. 

 

CSA C22.2 No. 120

 CSA Standard for Refrigeration 

 

BPA Free - Waterlogic

 tests for BPA and declares that all of its products are 

Bisphenol-A FREE and contain no harmful BPA plastics. 

 

NSF / ANSI 372 – Drinking Water System Components – Lead Content 

CSA B483.1 - Drinking Water Treatment Systems 

NSF / ANSI 372 – Drinking Water System Components for low Lead Content, and 

CSA B483.1 - Drinking Water Treatment Systems. 

 

NSF/ANSI-55 Class A –Ultraviolet Microbiological Water Treatment

 

Systems 

Firewall™ Technology contains our latest, most innovative and patented 

breakthrough, “The Firewall™”, the most comprehensive UV purification system 

for point-of-use water treatment systems ever developed. The Waterlogic Firewall 

component has been tested and certified by the Water Quality Association (WQA) 

to NSF/ANSI-55 Class A – Ultraviolet Microbiological Water Treatment Systems 

 

This Class A system conforms to NSF/ANSI 55 for the disinfection of 

microbiologically contaminated water that meets all other public health 

standards. The system is not intended to convert wastewater or raw sewage to 

drinking water. The system is intended to be installed on visually clear water. 

NSF/ANSI 55 defines wastewater to include human and/or animal body waste, 

toilet paper, and any other material intended to be deposited in a receptacle 

designed to receive urine and/or feces (blackwaste), and other waste materials 

deposited in plumbing fixtures (greywaste). 

 

NSF P231/US EPA Guide Standard and Protocol for Microbiological Purifiers  

The Public Health and Safety Organization establishes minimum requirements for 

health and sanitation characteristics of microbiological water purifiers. The 

requirements are based on the recommendations of the U.S. Environmental 

Protection Agency's Task Force Report.  

 

Summary of Contents for WL3 IT

Page 1: ...erated installed or maintained The installation maintenance sanitizing and any repair must be performed by qualified persons trained by Waterlogic International or their approved distributors only Do not remove any panel or cover to protect against electrical shock and exposure to UV radiation DANGER ELECTRICAL SHOCK HAZARD Always use a dedicated and properly grounded outlet Unit should be protect...

Page 2: ...s sanitize before use to eliminate any potential microbiological contaminates CAUTION INDOOR USE ONLY Intended for Household Use Never expose to direct sunlight heat sources or ambient air temperature above 37 C 100 F or below 2 C 35 F Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrige...

Page 3: ...es the Hot Water selection to be double tapped until the Red Light flashes and then pressed and held to dispense Hot Water Note there is a 2 second delay until hot water begins flowing It will default back to the Cold selection after 3 seconds of inactivity to prevent accidental dispensing of Hot Water In Tank UV Purification Industry leading In Tank UV Purification prevents the growth of biofilm ...

Page 4: ...ed breakthrough The Firewall the most comprehensive UV purification system for point of use water treatment systems ever developed The Waterlogic Firewall component has been tested and certified by the Water Quality Association WQA to NSF ANSI 55 Class A Ultraviolet Microbiological Water Treatment Systems This Class A system conforms to NSF ANSI 55 for the disinfection of microbiologically contami...

Page 5: ... This filter must remain installed in the WL350 to maintain these certifications Energy Star Certified The WL3 FX Water Treatment System has been tested and certified to the Energy Star a US Environmental Protection Agency EPA program that helps our customers save money and protect our climate through superior energy efficiency Waterlogic is certified to ISO 9001 2015 Quality Management Systems ce...

Page 6: ...et Point 5 C 41 F Adjustable 1 1 12 2 C 34 54 F Cold Tank Size Tower 4 Liters 1 1 Gallons Counter Top 2 Liters 53 Gallons Hot Water Temperature 87 C 189 F Factory Set Point 92 C 198 F Extra Hot Factory Set Point Hot Water Manual Reset Overload 105 C 221 F Hot Tank Size 1 5 Liters 40 Gallons Recommended Service Pressure 40 60 psi 275 414 kPa Use Pressure Regulator Maximum Service Pressure 100 psi 6...

Page 7: ...kg 52 9 pounds 27 kg 59 5 pounds Counter Top is 17 75 in tall and may not fit between countertops and cabinets Check installation to ensure adequate clearance ELECTRICAL SPECIFICATIONS ELECTRICAL SUPPLY 120V 60Hz 1PH 15 Amp Service COMPONENT POWER approximate AMP DRAW approximate Heater 504 4 2 Amps Compressor 216 1 8 Amps UV Lamp System 18 0 15 Amps WL3 IT TOTAL 738 6 15 Amps 15 2 17 5 17 8 15 2 ...

Page 8: ...tra Hot Water Press and Hold the Hot Dispense Icon for 10 seconds to activate the heater LED will flash slowly until water is Extra Hot When the LED stops flashing repeat the dispense operation for Hot Water For Ambient Water Press and Hold the Ambient Dispense Icon NOTE If the user initiates extra hot but then loses patience and does not want to wait any longer then they can Press twice and Hold ...

Page 9: ...c for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting installation and maintenance data After you submit a Return Authorization form and supporting documentation Waterlogic will determine whether a reasonably apparent defect in materials or workmanship covered by this l...