Page 9 - Revision: 6-8-2021
MODEL/PART DESIGNATIONS
BRAND NAME
DESCRIPTION
MODEL -
PART NUMBER
WL3 IT
Counter Top
WL3 IT Counter Top
–
Cold, Hot, Ambient
WL3IT-MU-HCA
F-3IT-MU-HCA-UTL111NX-BL-WLU
Serial Number Prefix: ____________
WL3 IT
Tower
WL3 IT Tower
–
Cold, Hot, Ambient
WL3IT-FS-HCA
F-3IT-FS-HCA-UTL111NX-BL-WLU
Serial Number Prefix: _____________
SPECIFICATIONS
ITEM
WL3 IT
Water Connection
¼” Quick Connect
Cold Water Temperature
Cold Water Temperature – Factory Set Point 5°C (41°F)
Adjustable - 1.1° - 12.2°C (34°
-
54°
F.)
Cold Tank Size
Tower: 4 Liters (1.1 Gallons)
Counter Top: 2 Liters (.53 Gallons)
Hot Water Temperature
87°C (189°F) Factory Set Point
92°C (198°F) Extra Hot Factory Set Point
Hot Water Manual Reset
Overload
105°C (221°F)
Hot Tank Size
1.5 Liters (.40 Gallons)
Recommended Service
Pressure
40-60 psi (275-414 kPa) – Use Pressure Regulator
Maximum Service Pressure 100 psi (689 kPa) – Use Pressure Regulator
Rated Service Flow
1.89 Liters per Minute (0.5 gallons per minute)
Environmental Temperature 2° - 37°C (35° - 100°F)
UV Lamp
Tower: 8 Watts
Counter Top: 4 Watts
Heater
500 W
Refrigerant Gas
R134a, 38g, 1.34 ounces
R134a Pressures
High (230 psi), Low (90 psi)