parameters and limit processing details. Finally, the
Interop
tap uses all of the test results to create a
Sifos Interop
Index
or score based upon test limit excursions of various tests on various ports. The score is based upon weighted
values for the various PSE Conformance parameters.
Occasionally, a test malfunction such as might be caused by a PSE port failing to power-up or powering down
unexpectedly will result in an aborted test and a
See Log!
indicator in the parameter result field. This means that an
error log has formed in the current active results directory. That log file can be opened simply by clicking on the Error
Log
hyperlink
in the upper right hand corner of the PSE Conformance Test report.
The file
psa_report.xls
is always installed as a read only file and any specific reports generated following a test
sequence should ALWAYS be saved to another name.
Special versions of
psa_report.xls
may be created and utilized for purposes of adjusting test limits or adding statistics
that go beyond the standard template report. These versions can be associated with a PSE Local Configuration File
(
see Section 2.4.4
) such that when that PSE file is loaded to PSA Interactive or PowerShell, the custom-modified report
template will be used in place of the standard
psa_report.xls
template for that particular PSE type.
To create a modified template, the following steps should be taken:
1. Copy
…\PSA1200\Results\psa_report.xls
to a newly named template such as
…\PSA1200\Results\
my_psa_report.xls
(saved into that same directory path).
2. Remove Read-Only permissions from
…\PSA1200\Results\
my_psa_report.xls
3. Edit
…\PSA1200\Results\
my_psa_report.xls
as required and save it.
4. Restore Read-Only permissions to
…\PSA1200\Results\
my_psa_report.xls
5. Open (or create) PSE Local Config File (e.g.
my_PSE.txt
) in the
…\PSA1200\Config\ directory
.
6. Add the following line to
…\PSA1200\Config\
my_PSE.txt
:
PSE_Conf_Test_Report: my_psa_report.xls
Loading the PSE Config File
my_PSE
will now cause the PSE Conformance Test Sequencer to utilize this modified
template file in place of the standard
psa_report.xls
. Sections 3.1.1 and 4.5 provide further information on loading
PSE local configuration files.
NOTE!
Never make modifications to
psa_report.xls
.
5.11. Enabling the PSE Conformance Test Suite
The
standard
PSA1200, PSA100, and PSA2400 PowerSync Analyzers do not enable the PSE Conformance Test Suite.
Attempts to execute any of the PSE Conformance Tests either directly or via the sequencer will yield “Invalid
Command” responses to PowerShell. PSE Conformance Test Menus for
PSE Tests
and Conformance
Sequencer
will
be disabled in PSA Interactive when connected to a PSA chassis that does not have this support.
PowerSync Analyzer customers may elect to upgrade their analyzer to support the PSE Conformance Test Suite. This
is done simply by procuring a unique key code from Sifos Technologies. Contact Sifos Technologies for further
information on performing this upgrade to your PowerSync Analyzer.
Summary of Contents for PowerSync PSA100
Page 26: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 26 ...
Page 56: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 56 ...
Page 84: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 84 ...
Page 110: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 110 ...
Page 120: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 120 ...