PowerSync Analyzer Reference Manual
March 9, 2010
Sifos Technologies page
45
Note
:
PSA Software will automatically create chassis-specific subdirectories under the \Results\ path for storage of
PSE Conformance test reports. These default reporting locations (i.e. directories) may optionally be overridden by
entries in the PSE local configuration files described earlier in Section 2.4.4.
The standard PSE Conformance Spreadsheet Report also includes a spreadsheet page for the 802.3af Conformance Test
Limits and a “Note!” page describing the various PSE Conformance Tests and all measured parameters. Finally, it
offers a “Sifos Interop Index”
(Figure 3.33)
page that provides an 802.3af interoperability “index” and information
describing its calculation.
Test data from the
Test Sequencer
may alternatively be captured in
a flat
Text File Report
(Figure 3.34)
presenting test results in the
exact order that testing is performed. This file may be cut and
pasted into a spreadsheet if desired. It does not include any
information beyond that generated directly by the various individual
conformance tests that are sequenced. As with the
Spreadsheet
Report
, the
Text File Report
will include a time-date header. The
Text File Report
will be unique to each test sequence as it embeds
a time-date stamp within the file name, assuming that the
Standard
Time-Date File
control is selected. Optionally, users may choose
to specify a file name (
User Specified File
) and enter that name in
the
Enter File Name
field. When this is done, the file name should
include just a file name, not a directory path nor a file extension.
The standard extension for all
Text File Reports
will be “.txt”.
During the
Test Sequencer
execution, the
Sequence Status
will
display the test cycle, the current test, and the current slot-port.
3.3.
PSE Multi-Port Test Suite Menus
Note
:
The PSE Multi-Port Test Suite Menus will only be activated if the connected PSA or PSA-PL is enabled for PSE
Multi-Port Testing.
3.3.1.
PSE Multi-Port Configure Resources Menu
The
PSE Multi-Port Configuration
menu
(Figure 3.36)
provides a method to configure test resources for the Multi-
Port Test Suite. The
PSE Multi-Port Test Suite
is the subject of Section 6.
Unlike PSE Conformance Testing where testing is conducted on a single test port within a single PSA chassis at any
one time, Multi-Port PSE Testing involves simultaneous and synchronized usage of many PSA test ports across one or
more PSA chassis’. As such, a special configuration menu is provided to establish the PSA chassis and test port
resources to be assigned for a Multi-Port test session.
The
Multi-Port Configure Resources
menu allows up to 8 PSA chassis’, each with up to 24 test ports to be assigned to
a Multi-Port test session. This means the maximum number of test ports allowed for Multi-Port testing is 192. Within
the menu, the
Clear
button may be used to clear out any previous configurations prior to creating a new resource
configuration. PSA resources must be configured starting with PSA 1 and working upwards until all required test ports
are assigned.
Figure 3.33
PSE Conformance Test Spreadsheet Report – Sifos Interop Index Page
S e p te m b e r 2 1 2 0 0 7
8 :4 8 P M
v e rs io n
3 .1 .1 7
P ort C ount… … … … … … … … … … … … 24
re p o rt v e rs io n 3 .1
Loop C ount… … … … … … … … … … … .. 1
L o w
P /F
H ig h
P /F
D e d u c t
In te ro p e ra b ility T e s t Ite m s
U N IT S
M in
M a x
Ave ra g e
L im it
L im it
P o in ts
H igh_S ig_M axV = volts
10.4
14.8
12.12333
3.8 Pass
11
In fo
1%
AC _R ipple_V pp(noise)= m V olts
8
207
33
0 Pass
200
F a il
4%
M in_C urrent_Lim it_Ilim = m A
63
89
73.20833
400
F a il
450 Pass
2%
25_m sec_S hort_Vport= V olts
0
0
0
44
F a il
57 Pass
2%
AC _M PS_V_open% = % Vport
9.9
10.4
10.08333
3.25 Pass
10
F a il
1%
O utput_V oltage_V = V olts
19.1
20.1
19.525
50
In fo
57 Pass
4%
25_m sec_S hort_Vport= V olts
46.1
46.8
46.3875
50
In fo
57 Pass
11%
80 2 .3 a f C o n fo rm a n c e R e p o rt
S ifo s P S E In te ro p In d e x *:
9 0 %
P SE T ested: S am ple 24 P ort PS E
Figure 3.34
PSE Conformance Test Text
File Report
PSA1200 TEST RESULTS
Port Count: 2
Loop Count: 1
Time-Date: May 20, 2008 7:19:12 PM
PSE:
TEST LOOP 1
Port: 1,1
det_v: Detection Voltages
Open_Circuit_Det_Voc=
4.1
volts
Peak_Det_Vvalid=
8.80
volts
Min_Det_Vvalid=
3.51
volts
Det_Volt_Step_dVtest=
5.29
volts
Detection_Slew=
0.00649
V/usec
Good_Sig_Det_Pulse=
1
edges
Non_802_Step_V=
0
volts
High_Sig_MaxV=
8.93
volts
Non_802_Discr_?=
0
****
Detect_Strategy=
1
****
det_i: Detection Compliance
Init_Current_Isc=
1.56
mA
Det_Current_Isc=
0.70
mA
det_time: Detection Time
Backoff_Time_Tdbo=
69.7
msec
Eff_Backoff_Tdbo_eff=
69.7
msec
Backoff_Type=
0
****
Detection_Time_Tdet=
289.1
msec
Total_Det_Time=
289.1
msec
Port: 1,2
det_v: Detection Voltages
…………
Summary of Contents for PowerSync PSA100
Page 26: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 26 ...
Page 56: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 56 ...
Page 84: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 84 ...
Page 110: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 110 ...
Page 120: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 120 ...