PowerSync Analyzer Reference Manual
March 9, 2010
Sifos Technologies page
50
3.4.
PSA Interactive Task Examples
The following paragraphs will demonstrate how to perform various tasks with PSA Interactive so that users may better
understand all of the resource menus described previously in Section 3.1.
3.4.1.
Observe a Class 1 Power-Up Sequence on Test Port 3,2 for an ALT A, MDI-X PSE Port
This task can be performed very easily using the
Waveforms
menu. Section 3.4.2 will also demonstrate how to do this
without the use of the
Waveforms
menu.
Menu
Task
Picture
Configure the port for the PSE type
Select Slot 3 and Port 2
Select ALT A
Select MDI-X
Apply Settings
DONE
Note
: The Waveform script will automatically take care of
setting detection passives appropriately.
Port
Configuration
Obtain the waveform
Select Class 1
Select Voltage
Power-Up Sequence (Standard)
Waveforms