PowerSync Analyzer Reference Manual
March 9, 2010
Sifos Technologies page
66
Command
Port
Command Parameters
Query
Returned
Parameters
measurement_type
<
timeout
>
psa_wait
<
port
>
Returns the final result of any triggered measurement
upon completion of that measurement. Automatically
polls the test port until measurement state reaches
READY
,
TIMEOUT
, or
OVERFLOW
(
timint only
).
measurement_type
is the type of triggered
measurement to be “polled”. Options are
vdca
verage
,
vdcp
eak
,
vdct
race
,
idca
verage
,
idcp
eak
,
idct
race
, or
timi
nt
.
timeout
is the desired timeout of the triggered
measurement. Range is 1 to 100 seconds.
measurement_function
psa_expire
<
port
>
Forces a triggered measurement in the ARMed or
MEASURING state to terminate without completing.
measurement_function
vdca
verage
,
vdcp
eak
,
vdct
race
,
idca
verage
,
idcp
eak
,
idct
race
, or
timi
nt
.
4.8.
PowerShell Test Support Utilities
PowerShell offers several utilities and higher-level commands that perform testing support functions on a port level.
These commands utilize Port Configuration and/or Measurement commands described above, and therefore
programmers should be aware that certain configurations previously established by those commands may change upon
execution of the Test Support Utility commands. As with the Test Port Configuration and Measurement commands, the
port
parameter may be used with these commands to direct which slot-port should be configured or from which slot-
port to return a status.
Command
Slot
Command Parameters
Returned Parameters
psa_auto_port
<
port
>
Automatically configures the chassis (or PSA2400 chassis
group) to the ALT and Polarity (MDI vs MDI-X) configuration
of the PSE connected to the current
port
. Also discovers AC
vs DC MPS disconnect method of PSE.
ALT, Polarity, MPS PSE
Configurations
<
r
ising
|
f
alling>
<
l
evel
trigLevel
> <
i
current
> <
tr
igout
>
psa_connect
<
port
>
Combines the
port connect
operation with capability to
adjust trigger #1 and static DC load current settings
coincident
with the port (detection passives) connection. See
iload
and
trig1
commands for command argument
descriptions.
<
trigout
>
psa_
disconnect
<
port
>
Forces a PSE Port power-down to occur. Opens the port
switch, sets DC current load to 0 mA, performs brief
discharge of port voltage.
trigout
:
Generates an external trigger out during the
physical disconnect operation.
power_check
<
port
>
Returns one of 4 states from a test port:
POWERED
: Indicates PSE port is powered up.
DOWN
: PD Disconnected, Port Not Powered.
POWERED_W/O_LOAD
: Indicates PSE port powered with
no PD connected.
UNDETECTED
: PD Connected but PSE port not powered.
POWERED |
POWERED_W/O_LOAD
| DOWN |
UNDETECTED
Summary of Contents for PowerSync PSA100
Page 26: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 26 ...
Page 56: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 56 ...
Page 84: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 84 ...
Page 110: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 110 ...
Page 120: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 120 ...