PowerSync Analyzer Reference Manual
March 9, 2010
Sifos Technologies page
119
Command
Command Parameters
<
slot
,
1
> <
p
power
|
i
load
|
c
class
|
ci
class_current
> <
dr
resistance
> <
dc
capacitance
>
power_port_2
Simulates a PD connected to a PSE port to bring power up to a user-specified condition. If no
command parameters are specified, the default power-up condition is a static load of 20 mA.
Status of port, measured voltage, and target current are returned upon completion of command.
Class
or
class_current
may be combined in a single command with post-power-up
power
level,
otherwise default power-up levels will be applied given PD classification.
p
indicates that power draw of port will be specified.
power
is the power in watts that the port will power-up to. Regardless of power specified,
classification will detect a “Class 0” PD. Range is .2 to 38.0 Watts.
i
indicates that current draw of port will be specified.
current
is the current draw in mA that the port will power-up with. Regardless of current
specified, classification will detect a “Class 0” PD. Range is 0 to 760 mA.
c
indicates that classification of port will be specified.
class
is the port classification. Range is 0 to 4. Class signatures and Load Currents
implemented by classification are:
Class
Class Current
Power-Up Current
0
2 mA
140 mA
1
10 mA
44 mA
2
18 mA
108 mA
3
28 mA
202 mA
4
40 mA
350 mA
ci
indicates that the classification current to be applied will be specified.
class_current
is the classification current to apply during classification. Range is 0 to 45 mA.
Power-up current will be determined according the class-band of the specified classification
current.
dr
indicates that a non-default detection resistance should be used.
resistance
is the detection load resistance to use for the power-up. Range is 11 to 39K
Ω
.
dc
indicates that a non-default detection capacitance should be used.
capacitance
is the detection load resistance to use for the power-up. Range is 0, 5, 7, or 9
μ
F.
<
slot
,
1
>
config_type
{
target_slots
}
replicate_ports_2
Replicate configuration of resources from one test slot to a number of other test slots for High
Power PSE testing with PSA Port Combiners.
config_type
:
The type of configuration to be replicated from <
slot
,1> to {
target_ports
}. Options
are:
port
|
trig
|
load
|
vdca
|
vdcp
|
vdct
|
idca
|
idcp
|
idct
|
acv
|
time
|
all
. “
all
” will fully
replicate all subsystem configurations.
target_slots
: A list of all slots to which the configuration is to be copied. Each slot is in the
form as “
slot#
,1” and is space delimited in the list.
Summary of Contents for PowerSync PSA100
Page 26: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 26 ...
Page 56: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 56 ...
Page 84: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 84 ...
Page 110: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 110 ...
Page 120: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 120 ...