Meter utilization (Advanced version only)
6 registers for monitoring total time the meter has operated in different flow intervals.
Registered intervals are freely selectable as % of Qn (Q3).
Tariff (Advanced version only)
6 tariff registers count the volume delivered within the selected tariff windows, based on time
of day, flow rates, or a combination.
Tariff can also be used for consumption profile where consumption is related to different time
intervals or flow rates.
Tariff values visible on the display.
Settling date (Advanced version only)
At midnight (23:59:59) on a predefined date the totalizer 1 index value is stored. Old values
are stored to show the latest two totalized 1 index values. Settling values are visible on the
display.
Statistic (Advanced version only)
● Min. flow rate with time and date registration
● Max. flow rate with time and date registration
● Min. daily consumption with date registration
● Max. daily consumption with date registration
● Latest 7 days' total and daily consumption
● Actual month's consumption
● Latest month's consumption
Appendix
C.6 Features
SITRANS MAG 8000
162
Operating Instructions, 11/2018, A5E03071515-AE