The standard MAG 8000 CT format is:
● Europe: m
3
for totalizer and m
3
/h for flow rate
The following MAG 8000 units and combinations are available:
Volume: m
3
, m
3
× 100, L × 100, Gallon, G × 100, G × 1000, MG, CF × 100, CF × 1000, AF,
AI, kl, ML, BBL42
Flow rate: m
3
/min, m
3
/h, m
3
/d, L/s, L/min, L/h, ML/d, GPS, GPM, GPH, GPD, MGD, CFS, CFM,
CFH, BBL42/s, BBL42/min, BBL42/h, BBL42/d
To ensure selection of correct conversion factor, see unit conversion table in appendix
All measurement units are printed on a label affixed to the display (except the European
version). Some meter sizes have a factor included to secure the 8 digit display value will not
overrun after short time of operation. Manual configuration of new units is allowed. A new
sticker showing the new settings must then be affixed to the display.
Protected parameters
The following parameters are protected (see also parameter lists in appendix (Page 136)):
MAG 8000 Standard / MAG 8000 CT / MAG 8000 Irrigation
MAG 8000 CT (additionally)
Parameter no.
Parameter name
Parameter no.
Parameter name
-
New password
101
Totalizer 1
5
Sensor tube diameter
102
Totalizer 2
7
Meter No.
303
Operation excitation frequency
8
Totalizer unit
305
Decimal point place
9
Flow unit
310
Flow direction totalizer 1
10
Qn (Q3)
312
Flow direction totalizer 2
300
Totalizer unit factor
327
Adjustment factor
301
Flow unit factor
328
Low flow cut-off
302
Pipe size
332
Empty pipe impedance
321
Calibration date
420
Device Communication Address
323
Calibration factor
550
Coil current active
Flow Tool
A.5 Unit selection
SITRANS MAG 8000
Operating Instructions, 11/2018, A5E03071515-AE
123