Installation
12
Siemens Building Technologies
SISTORE AX4_EN.doc
Fire & Security Products
09.2004
2.10 Connecting to the Network Port
Fig. 12
Network connector.
The DVR can be networked using the 10/100Mb Ethernet connector. Connect a
Cat5 cable with an RJ-45 jack to the DVR connector. The DVR can be networked
with a computer for remote monitoring, searching, configuration and software
upgrades. See
Chapter 3 — Configuration
for configuring the Ethernet
connections.
2.11 Connecting to the Modem Port
Fig. 13
Modem connector.
The DVR can be networked using the telephone line connector. Connect a cable
with an RJ-11 jack to the DVR connector. The DVR can be networked with a
computer for remote monitoring, searching, configuration and software upgrades.
See
Chapter 3 — Configuration
for configuring the modem connections.
CAUTION:
To reduce the risk of fire, use only No. 26 AWG or larger UL Listed or CSA Certified
Telecommunication Line Cord.
2.12 Connecting to the RS-232C Port
Fig. 14
RS-232C connector.
An RS-232C port is provided to connect an external modem for remote monitoring,
configuration and software upgrades, text input, and to connect a remote control
keyboard. Use a modem cable with a DB-9S (female) connector to connect to the
DVR. See
Chapter 3 — Configuration
for configuring the modem.
NOTE:
The DVR is not supplied with a modem cable, and many modems are not supplied with cables. Make
certain you have the correct cable when purchasing the modem.
2.13 Factory Reset
Fig. 15
Factory reset switch.
The DVR has a Factory Reset switch to the right of the RS-232C connector. This
switch will only be used on the rare occasions that you want to return all the
settings to the original factory settings.