3.5.3
System Check Screen
Highlight System Check in the Main menu and press the
button. The System
Check setup screen appears.
Fig. 29
System Check screen.
Highlight the box under the On/Off heading and press the
button. This toggles
between On and Off. When it is On, the DVR reports a fault condition if it does not
detect any recording or if there is an alarm during the designated time.
Highlight the box under the Interval heading and press the
button. A slide bar
appears allowing you to set the check interval from 1 Hour to 30 Days.
The Status field displays the fault conditions. When it is Good, there was recording
or an alarm occurred during the designated time. When it is Bad, there was no
recording or no alarm occurred during the designated time.
Highlight the box beside the On Record Problem: Alarm Out and press the
button. A drop menu displays the available alarm outputs for the recording
problem. Highlight the desired alarm output from no alarm output, external alarm
out terminal or internal buzzer, and press the
button.