Procedure
1. At the front cover release the two central fastening screws.
To avoid losing the screws, do not turn the screws completely out of the cover.
2. Remove the front cover.
3. Withdraw the battery connector.
4. Release the 4 fastening screws that fix the connectivity module to the holder.
5. Remove the connectivity module from the mounting bracket.
6. Place the new connectivity module in the mounting bracket.
7. Retighten the 4 fastening screws.
8. Insert the battery connector.
9. Put the front cover back in position. Ensure that the cover fits precisely.
10.Tighten the 2 central fastening screws at the front cover by hand.
11.Reconfigure the connectivity module (Page 23).
8.6
Replace the battery
Batteries are consumables. You can order batteries as spare parts (Page 109). Replace the
battery in plenty of time in order to guarantee the functionality of the device.
Shorter measurement and synchronization intervals result in a shorter battery life (see Chapter
Changing measurement and synchronization intervals (Android) (Page 84) or Changing
measurement and synchronization intervals (iOS) (Page 91).
The ambient conditions, such as temperature, can also influence the battery life.
If the battery status display of the connectivity module is red, the charge is 30% or less. Replace
the battery in good time. If disturbances occur in data transmission, replace the batteries.
Maintenance
8.6 Replace the battery
SIMOTICS CONNECT 400
104
Operating Instructions, 08/2021, A5E50161952B AE