Operating Instructions 

581E,5005/6.00 

 

1

 

Operating Instructions 

MAGSTOP Traffic Barrier 

MIB 10-C090 

Controller Unit 

 

 
 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

Содержание MAGSTOP MIB 10-C090

Страница 1: ...Operating Instructions 581E 5005 6 00 1 Operating Instructions MAGSTOP Traffic Barrier MIB 10 C090 Controller Unit ...

Страница 2: ...Operating Instructions 2 2000 by Magnetic Autocontrol GmbH 79650 Schopfheim Germany ...

Страница 3: ... tollbooths motorways major roads etc The MAGTRONIC controller units have been specially designed for controlling this Magnetic barrier Any other use of these barrier systems is not permitted Modifications or changes to the barrier or to the control modules is prohibited Only original Magnetic spare parts and accessories may be used 1 3 Safety symbols used in this handbook The following symbols ar...

Страница 4: ... modified gate arm fixture must be agreed with Magnetic All electrical connections wiring work and exchange of components may only be performed by appropriately trained electrical technicians Before opening the machines must be disconnected from the mains All technical modifications or changes to the barrier system are prohibited 1 5 Technical developments The manufacturer reserves the right to mo...

Страница 5: ...crete foundation BH PC 250 strength 25 N mm Empty conduit pipes each with a diameter of 29 mm must be installed to take the mains supply cable the control cables and possibly the induction loop connections barrier 2 or 3 empty conduit pipes control pillar 2 empty conduit pipes A reinforcing steel cage is absolutely essential for the stability of the foundation see Fig S0102 Fig S0102 Reinforcing c...

Страница 6: ...the surface of the lane assuming standard loop installation The following points must be considered when installing the induction loop The loop must be positioned so that it is symmetrical about the vertical plane through the gate arm It must be recalled that the barrier boom is attached to one side of the gate housing The distance from the gate arm to the front and rear portions of the induction ...

Страница 7: ...ved by making three to five windings Using an angle grinder a channel is cut to a depth of 30 mm into the bitumen or asphalt surface see Fig S0104 The channel must have a uniform depth over its entire length The cable is laid carefully into the channel and pressed down uniformly using a blunt object e g a wooden or plastic spatula Small wooden wedges can be used to hold the cable in position Fig S...

Страница 8: ...ones is required see Fig S0105 Fig S0105 Installing an induction loop under paving stones 1 gate housing 2 paving stones 3 loop cable l 4 sand bed 5 crete foundation 2 3 Assembling the housing The gate housing is positioned vertically on the upper face of the foundation and secured using the fastenings in assembly set A that is supplied with the system See Fig S0106 In order to be able to adjust t...

Страница 9: ...pring tension with safety clips 3 clamping lever for flanged shaft 4 rubber buffer 5 connector piece 6 clamping lever for motor Warning When tensioned the springs and the gate arm exert considerable forces on the drive unit and there is thus a potential risk of injury Any work on the BDU drive unit must therefore be carried out only when the springs are not under tension and when the gate arm has ...

Страница 10: ... applied proceed as follows 1 Open the gate door swing out the mounting plate unlock the cover and remove 2 Raise the barrier boom by giving an opening contact 3 Make sure that no contact for closing can be given to the controller 4 Loosen the two clamping screws on the clamping lever of the flanged shaft just enough so that the barrier boom is held safely in position while still allowing it to be...

Страница 11: ...o it s normal position 5 Controller for MIB10 gates The controller unit has been specially designed for use with MIB 10 gates Most gate system configurations can be realized using the standard version of the controller The position of the gate arm is continuously calculated by the controller The information comes from the hall sensors inside of the motor This replaces the limit switch that is used...

Страница 12: ...Operating Instructions 581E 5005 6 00 12 ...

Страница 13: ...wiring diagram S1 and S2 The switch for OPEN is prior to the DOWN switch that means we both contacts are closed the gate will open Connections Potential free contact between 24V terminal S and terminal 9 S1 and terminal 10 S2 Additional safety devices can be connected to terminal 14 and 13 These must function as break contacts Program 2 Mode 4 The barrier is opened and closed by two separate comma...

Страница 14: ... 2000 Housing dimensions 350 x 350x 1010mm W x D x H Foundation base frame stainless steel Weight without arm 55 kg Operating temp range 20 C to 50 C Drive brushless DC motor 6 2 Controller unit Voltage 10 volt 115 requency hertz 50 60 Max power consumption watt 20 Fuse T10A I O voltage 24 V DC RS232 communication 1 SUB D Mode settings 2 No of input channels 5 No of open collector outp max 50mA 24...

Страница 15: ...or assistance When contacting our technical support service please have available the barrier type serial number version etc which you will find printed on the type plate on the barrier housing 8 Spare parts and accessories The spare parts and accessories for your barrier system are listed in our separate spare parts and accessories catalogue which is available from Magnetic or from one of our aut...