"Device overview" page
When the "SIDRIVE IQ Config" application starts, by default, you see a list of all of the currently
visible assets on the "Device overview" page. You can also display all of the assets visible in the
history. A list entry contains the information about an asset. The following diagram explains the
pictograms in a list entry.
①
To identify an asset, press the motor icon (LED of the connectivity module flashes)
Note: Identification is not possible if firmware version < 0.6.0 is installed. A message to that
effect is displayed requesting you to update the firmware.
②
BLE name of the currently selected connectivity module
③
Bluetooth interface signal strength display
④
WLAN configuration status of the connectivity module:
• "Black" status: WLAN configured and operating correctly
• "Red" status: WLAN not configured or has a fault
⑤
Connection status of the connectivity module to the MindSphere application "SIDRIVE IQ Fleet"
(onboarding status)
• "Black" status: Connected
• "Yellow" status: No Onboarding yet
• "Red" status: Error during upload
⑥
Status of the connectivity module battery:
• "Black" status: sufficient charge
• "Red" status: low charge, 30% or less
Note: Replace the battery in good time. If disturbances occur in data transmission, replace the
batteries (Page 104).
⑦
Button for opening help
⑧
Button for establishing a connection to the connectivity module
If necessary, confirm a pairing request to establish the Bluetooth connection.
Procedure
1. Open the "SIDRIVE IQ Config" application.
2. Select an asset from the list.
Commissioning
6.3 Commissioning with iOS
SIMOTICS CONNECT 400
52
Operating Instructions, 08/2021, A5E50161952B AE