Procedure
1. Open the "SIDRIVE IQ Config" application.
2. Select the required asset in the device overview.
3. Tap on the motor symbol
.
The connectivity module LED flashes.
7.2.3
Changing measurement and synchronization intervals
The following intervals are preset in the factory:
• 5 minutes - interval for measuring temperature, vibrations, rotational frequency, operating
status
You can change these settings within a specified range.
• 15 minutes - interval for calculation of speed, torque and energy consumption
This setting is always three times the short measurement interval that has been set.
• 24 hours - interval for transmission of the stored data to SIDRIVE IQ Fleet
You can change these settings within a specified range of between 1 and 48 hours.
Note
Effects that influence the battery life
Shorter intervals result in a shorter battery life.
Operation
7.2 Operation with iOS
SIMOTICS CONNECT 400
Operating Instructions, 08/2021, A5E50161952B AE