Install Guide XF1550P 125 kHz Reader 
 

XF1500P

 

XF1500CS4

 

1 - Installation Sheet 
1 - Mounting Plate 
1 - Cover 
1 - Potted Reader 
Assembly  
2 - Mounting Screws 
1 - Cover Assembly Screw 

1 - Installation Sheet 
1 - Mounting Plate 
1 - Cover 
1 - Potted Reader Assembly 
 2 - Mounting Screws 
1 - Cover Assembly Screw  
1 - Pigtail with Connector 

 

MOUNTING THE READER

 

1. Determine an appropriate mounting position on a single gang box or wall. Be sure to account 
for any applicable ADA height requirements. 
2. For a single gang box mount, attach the back-plate to the holes in the single gang box using 
the screws provided. 
3. For a wall mount, drill two mounting holes between 2.5” (63.5mm) and 3.5” (88.9mm) apart 
on the mounting surface. Drill one 3/4” (19.1 mm) diameter cable hole for the pigtail wire 
connection. 
4. Connect the mounting plate to the wall using the screws provided. 
5. Wire the unit according to the color code chart below ensuring that all connections are made 
through the center hole in the mounting plate. 
7. Hook the top of the potted case assembly to the top of the mounting plate. 
8. Swivel the unit down into place and snap the cover over the potted reader assembly. 
9. Install the screw from the bottom to fix the cover to the potted case to the mounting plate. 
 

CABLE CONNECTIONS

 

1. XceedID XF1550P readers are supplied with a 12 conductor cable pigtail.  
2. Connect this pigtail with the host/panel being careful to match the color of each wire with the 
chart shown in Figure 1. 
3. Use a DC power source between 5 volts and 16 volts. 
4. Be sure the reader is properly grounded by attaching the ground wire to an earth ground 
connection at the power supply or panel end of the cable. 
 

Testing the Reader

 

1. Power up the reader. The LED will light followed by a beeper tone. This indicates that the 
reader is ready. 
2. Present a proper card or token programmed to operate the reader and a green LED flash will 
indicate successful operation. Note that a red flash could simply indicate an incorrect match or 
miss-programmed card/token rather than a faulty reader installation. 
 

Additional Notes

 

• The voltage specification for these products is 5*-16VDC. 
• Typical cable gauge ranges from 18 to 22 gauge. Check with your cable supplier to determine 
the best choice for your application and installation distance.

 

 