Specifications
9410 series
US2:948M2DO6DI Digital (2 out, 4 in)
Maximum number of modules
4
Maximum meter operating temperature
-25 ºC to Max temp (-13 ºF to Max temp)
Maximum operation temperature is based on the quantity and type of
attached option modules. See
Maximum operating temperature, page
166
.
Other
Meter start time
Typical: 18 seconds (power up to measurement)
Meter memory
512 MB
Data update rate
Regular data: 1 second
High-speed: 50 – 60 Hz half-cycle
Advanced security users
Up to 16 users
MID
Applicable MID standards and class
index
•
EN 50470-1:2006 Class C
•
EN 50470-3:2006 Class C
Type of measuring equipment
Static watt-hour meter
Mechanical environment
M1
Electromagnetic environment
E2
Cover sealing type
Wire and crimp
Applicable measurements
Active import/export energy metering
System types (for MID-compliant
applications)
•
3-phase 4-wire Wye grounded
•
3-phase 3-wire Delta ungrounded
Current rating
0.05 – 5(10)A
Nominal frequency
50 Hz
Energy pulsing LED
Pulse weight – 5000 imp/kWh
To comply with European directive MID 2004/22/EC, the meter must be installed in MID certified cabinets rated for IP51 or better
Visit the website at www.usa.siemens.com/pds and search for “9410 technical
datasheet” for the most up-to-date and complete specifications.
See your remote meter display’s installation sheet for remote meter display
specifications.
See your option module’s installation sheet for option module specifications.
Visit the company website at www.usa.siemens.com/pds and search for “9410” to get
additional or updated documentation.
7EN05-0336-01
169