Chapter
5
Operating Instructions
ICR890 High-end CCD Camera System
68
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011325/0000/2006-10-24
Electrical installation
5.4.5
Wiring the Ethernet interface HOST ETHERNET
The Ethernetinterface HOST ETHERNET
of the ICR890 System has several functions:
•
Output of the reading result of the HOST data interface via TCP/IP as an alternative to
the serial interface version RS 232, RS 422/485
•
Output of data of the AUX data interface (reading reading diagnosis data) via
TCP/IP as an alternative to the serial interface version RS 232, RS 422/485
•
Access to the ICR890 System via the SOPAS-ET Configuration Software
•
Connection as RDT400 Client (system distance monitoring)
Connecting the ETHERNET HOST interface
¾
Connect the ICD890 Camera directly to the Ethernet card of the PC (point-to-point
connection) using the crossover cable (see
- or -
Connect the ICD890 Camera to the Ethernet network using the standardized data cable
(patch
cable
) no. 6029630.
See
for required settings at the PC and the ICR890 System.
Abb. 5-7:
Block diagram: Function of the Ethernet interface
ICR890
PC
Aux
Host
CAN
Ethernet
SOPAS-ET
FTP server
Port 21: FTP
Port 2112: Host
Port 2111: AUX
RS 232, RS 422/485
RS 232, RS 422/485
VMS4xx/5xx
MSC800