Operation
6.3.6
Changing the device password for the user level "Authorized Client"
The device password for the user level "A
UTHORIZED
C
LIENT
" can be altered device specifically
by the customer. This prevents unwanted or unauthorized changes to the configuration.
1. Establish communication with the device (see
).
2. In the menu bar under ICR890 select the command P
ASSWORD
/C
HANGE
P
ASSWORD
.
3. Ensure that the user level "A
UTHORIZED
C
LIENT
" has been selected in the dialog window
R
EGISTER
.
4. Enter the new password in the field N
EW
P
ASSWORD
.
The entry occurs as hidden text.
5. Re-enter the new password in the field C
ONFIRM
N
EW
P
ASSWORD
.
The entry occurs as hidden text.
6. Confirm entries via the L
OGIN
button.
A message confirms successful device password changes.
6.4
Default setting
The values of the default setting are permanently saved in the ICR890 System (ROM) and
in the database of the SOPAS-ET Configuration Software in the device-specific jar file (see
). A PC is not required for system startup with the default setting.
6.4.1
Resetting the default setting in the ICR890 System
Prerequisite
The SOPAS-ET Configuration Software is connected online to the ICR890 System.
1. In order to completely discard changes to the parameter set, in the menu bar under
ICR890 select the command P
ARAMETER
/L
OAD
FACTORY
DEFAULT
.
The SOPAS-ET Configuration Software loads the default setting from the database and
displays the parameter values in the register tabs.
2. In the menu bar under E
XTRAS
select the command L
OGIN
TO
DEVICE
.
3. In the dialog window under U
SERLEVEL
in the list box select the entry A
UTHORIZED
C
LIENT
and enter the word “client“ under P
ASSWORD
.
Click on OK to confirm the dialog window.
4. In the menu bar under ICR890 select the command P
ARAMETER
/S
AVE
P
ERMANENT
.
The SOPAS-ET Configuration Software transfers the default setting to the permanent
parameter memory (EEPROM) of the ICR890 System.
6.4.2
Default setting MSC800
See
MSC800 Operating Instructions
(no. 8011540).