Operating Instructions
Chapter
6
ICR890
Operation
8011325/0000/2006-10-24
©
SICK AG · Division Auto Ident · Germany · All rights reserved
87
6.3.4
Load changed parameter sets into the device
Changed parameter values are immediately transferred to the ICR890 System depending
on the option (“Download Immediately“). To ensure that the changes remain even after a
system restart, the configuration has to be permanently saved in the system.
1. In order to load current settings into the ICR890 System, in the menu bar under ICR890
select the command P
ARAMETER
/S
AVE
PERMANENT
.
- or -
In order to load the current settings in the MSC800, select the command P
ARAMETER
/
S
AVE
PERMANENT
in the menu bar under MSC800.
2. Restart the ICR890 System/MSC800.
6.3.5
Save, display and print the current parameter set
When archiving a parameter set it is recommended to not only save the project file but also
print out the contents of the file.
1. In order to save the current parameter set, select the menu item S
AVE
P
ROJECT
AS
in the
menu bar under P
ROJECT
.
2. Enter a file name in the dialog window and confirm it via S
AVE
.
The SOPAS-ET Configuration Software saves the current settings in a configuration file
“*.SPR“.
3. In order to print out the current parameter set, select the command P
RINT
/P
RINT
P
REVIEW
in the menu bar under P
ROJEKT
.
The SOPAS-ET Configuration Software displays a preview of a table with a list of all the
parameter values.
4. Click on
in the tool bar at the top of the dialog window.
The dialog window P
RINT
for printer configuration appears.
5. Edit setting accordingly and confirm via OK.
The current project settings are printed as a table on several pages.
19.
Ethernet
General
IP-Address
IP-Mask
IP-Gate-Address
Speed
20.
GBit Ethernet
GBit Ethernet 1/2
IP-Address
IP-Mask
IP-Gate-Address
Speed
21.
CAN
CAN 1/2
Mode
Node-ID
Baudrate
Output format
22.
Digital Outputs
Output 1/2
Output 1/2
Inverted
Control
Duration
23.
Digital Inputs
Sensor 1/2
Control
Inverted
Debouncing
Step
Entry in the project tree
Register tab
Parameter
Tab. 6-5: ICR890 System (stand-alone device) without MSC800: Overview of parameters which have to be set (cont.)