Operating Instructions
Chapter
6
ICR890
Operation
8011325/0000/2006-10-24
©
SICK AG · Division Auto Ident · Germany · All rights reserved
83
6.3.3
Configuring the ICR890 System/MSC800
The following tables
and
(ICR890 System
with
MSC800) or
(ICR890 System
without
MSC800) act as guidelines for the configuration.
The function of each respective parameter is explained in a context-sensitive manner in an
online help (F1 key). The valid value range and the default setting list the display window
“Parameter Info“ (right mouse button, when the cursor is positioned over the parameter).
In order to configure a device via the SOPAS-ET Configuration Software, the respective
operating level has to be selected in advance. After the start, the SOPAS-ET Configuration
Software functions at the operating level “Maintenance“.
1. In the menu bar under E
XTRAS
select the command L
OGIN
TO
DEVICE
.
2. In the dialog window under U
SERLEVEL
in the list box select the entry A
UTHORIZED
C
LIENT
and enter the word “client“ under P
ASSWORD
.
Click on OK to confirm the dialog window.
The previously greyed out parameters on the register tabs are now accessible.
Settings at the ICR890 System for application as a stand-alone device with MSC800
(single-side reading)
Step
Entry in the project tree
Register tab
Parameter
1.
Reading config.
Codelabel properties
Minimum code position
Maximum code position
Symbol Contrast
2.
Reading config.
Image capturing properties
Digital zoom
Image Resolution
3.
Object Trigger Control
Start/Stop of Object trigger
Control
Start
4.
Focus Control
Optionen Fokussteuerung
Default Position
Focus Control Mode
5.
Focus Control
Distance Measurement Source
MLG
VMS
6.
Lamp Control
Illumination mode
Lamp on
Lamp timeout active
Timeout
7.
Position
Offsets
X-Offset
Y-Offset
Z-Offset
8.
Position
Coordinates
X-Coordinate
Y-Coordinate
Z-Coordinate
Distance to deflecting mirror
9.
Position
Angles
Alpha
Beta
Gamma
10.
Increment config.
Increment
Increment source
Resolution/Speed
11.
Image Acquisition
Request
Request
Image format
Bitmap scaling/JPEG Quality
Activate Diagnosis Output
Output limited by code position
Tab. 6-3: ICR890 System (stand-alone device) with MSC800: Overview of parameters which have to be set