“OUT“ connection (digital switching outputs)
“IN 1“ connection (digital switching input 1)
“IN 2“ connection (digital switching input 2)
“HOST ETHERNET“ connection (Ethernet 10/100 MBps)
Pin
Signal
Function
1
Result 1+
Switching output 1
2
Result 1–
Switching output 1
3
Result 2–
Switching output 2
4
Result 2+
Switching output 2
Tab. 5-23: ICD890 Camera: Pin assignment of the 4-pole M12 plug “OUT“
Pin
Signal
Function
1
+24 V DC
Power supply for sensor
2
IN 1–
Switching input 1 (optocoupler)
3
GND
Ground
4
IN 1+
Switching input 1 (optocoupler)
5
–
–
Tab. 5-24: ICD890 Camera: Pin assignment of the 5-pole M12 socket “IN 1“
Pin
Signal
Function
1
+24 V DC
Power supply for sensor
2
IN 2–
Switching input 2 (optocoupler)
3
GND
Ground
4
IN 2+
Switching input 2 (optocoupler)
5
–
–
Tab. 5-25: ICD890 Camera: Pin assignment of the 5-pole M12 socket “IN 2“
Pin
Signal
Function
1
TD+
Tran
2
RD+
R
3
TD–
Transmitter–
4
RD–
Receiver–
Tab. 5-26: ICD890 Camera: Pin assignment of the 4-pole M12 socket “HOST ETHERNET“