Chapter
4
Operating Instructions
ICR890 High-end CCD Camera System
50
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011325/0000/2006-10-24
Installation
4.3.1
Installing the deflection mirror
The deflection mirror is attached to the installation frame via two 180° brackets. The
position of the deflection mirror results from the distance to the reference point in the
direction of transport (plumb line above the pivotal point of the bracket) and the angle to
the conveyor level (see
). The deflection mirror has to be installed parallel
to the conveyor level.
1. Attach a 180° bracket to each side of the installation frame using two bolts and two
slot nuts on each side.
2. Place the mounting plate of the 180°bracket vertically and tighten the clamping
screws.
3. Insert the guide pins of the deflection mirror into the grooves of the 180° brackets.
The grips point upward.
4. Use two fastening screws to attach the deflection mirror to the 180° brackets.
5. Loosen the clamping screws, use the goniometer to adjust the deflection mirror to the
desired angle and retighten the clamping screws.
6. Remove the protective film from the deflection mirror.
4.3.2
Installing the ICI890 Illumination and the ICD890 Camera
The illumination is attached to the installation frame via two 180° brackets. The position of
the illumination is the result of the distance to the deflection mirror (see pivotal point of the
brackets,
). The illumination has to be parallel to the deflection mirror.
Risk of injuries due to falling components!
The combined weight of the ICD890 Camera and the ICI890 Illumination is approx. 37 kg
(81.6 lb) without installation accessories.
¾
Do
not
carry out installation work alone.
¾
A second person should always secure components during installation.
1. Attach a 180° bracket to each side of the installation frame using two bolts and two
slot nuts on each side.
2. Place the mounting plate of the 180°bracket vertically and tighten the clamping
screws.
3. Insert the guide pins of the illumination into the grooves of the 180° brackets. Always
ensure free space for connecting (
).
4. Use four fastening screws to attach the illumination to the 180° brackets.
5. Remove the protective cap from the illumination and ensure that the sealing ring on the
illumination is positioned correctly.