Operating Instructions
Chapter
5
ICR890
Electrical installation
8011325/0000/2006-10-24
©
SICK AG · Division Auto Ident · Germany · All rights reserved
71
5.5
Pin assignments and conductor colouring assignment
5.5.1
ICD890 Camera connections
Note
All connections have been provided with protective caps for delivery.
“GBIT 1“/“GBIT 2“ connections (Ethernet, max. 1GBps)
-
“CAN 1-OUT“/“CAN 2-OUT“ connections (CAN-SENSOR networks)
-
Abb. 5-10: ICD890 Camera: Electrical connections (standard system)
Ethernet
(GBit channels)
Power supply
Ethernet
(host)
Pin
Ethernet signal
Function
1
TD+
Tran
2
TD–
Transmitter–
3
RD+
R
4
n. c.
–
5
n. c.
–
6
RD–
Receiver–
7
n. c.
–
8
n. c.
–
Tab. 5-17: ICD890 Camera: Pin assignment of the 8-pole RJ-45 sockets “GBIT1“ and “GBIT2“
Pin
CAN signal
Function
1
Shield
Shielding
2
CAN_V+
Supply voltage 24 V
3
CAN_GND
Ground
4
CAN_H
CAN bus (IN/OUT)
5
CAN_L
CAN bus (IN/OUT)
Tab. 5-18: ICD890 Camera: Pin assignment of the 5-pole M12 sockets “CAN 1-OUT“/“CAN 2-OUT“