Chapter
3
Operating Instructions
ICR890 High-end CCD Camera System
30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011325/0000/2006-10-24
Product description
1-D/2-D code detection
•
Data Matrix ECC200 (PDF417 in preparation)/all conventional bar codes
•
Max. number of 1-D codes: 50 per reading pulse
•
Max. number of 2-D codes: 10 per reading pulse
•
Separation of identical codes of the same code type using the code position
•
Output sorting: Code position, FIFO, LIFO, code lengths list
•
Manipulation of output strings via filter or format masks
Data communication
•
Main data interface HOST: Configurable output format of the reading result,
communication redirectable to Ethernet interface
•
AUX auxiliary data interface: Permanent output format with special diagnosis functions,
communication redirectable to Ethernet interface
•
Two 1 GBit Ethernet interfaces for fast image output
Reading pulse
•
External reading pulse via switching input(s) or data interface
Electrical interfaces
•
HOST data interface: RS 232, RS 422/485 serial, Ethernet or CAN (various transfer
rate and protocol configurations possible)
•
AUX data interface: RS 232, RS 422/485 serial, Ethernet or CAN (permanent transfer
rate, data format and protocol)
•
CAN interface for integration into SICK CAN-SENSOR Network with the MSC800 or into
a CAN Open Network
•
Ethernet interface (10/100 MBps), TCP/IP and FTP
•
Two 1 GBit Ethernet interfaces, FTP and GigE Vision Standard
•
Two digital switching inputs for external reading pulse sensor and incremental encoder
via optocoupler
•
Two digital switching outputs for signalling definable results in the reading process
(system status)
•
Connection to PROFIBUS-DP via MSC800
Connection technology (design)
•
Data and function interfaces: M12 connector for industrial use
•
GBit Ethernet: Phoenix VARIOSUB RJ-45 sockets, enclosure rating IP 67
•
Power supply: Harting connectors