Indicators and control elements
3.5.1
User interface
The ICR890 System is configured application specifically using the SOPAS-ET Configuration
Software (see
Chapter 6.3.1 Overview of the configuration procedure, page 81
). The
software for this runs on a PC which must be connected to one of the data interfaces
(“HOST/AUX“ RS 232 or “HOST Ethernet“) of the MSC800 or the ICD890 Camera.
As an alternative to the SOPAS-ET Configuration Software, command strings are available
upon which the user interface of the SOPAS-ET Configuration Software is based (see
Chapter 10.2 Configuring the ICR890 System with command strings, page 111
In case of an error, startup and diagnosis can only be carried out via the SOPAS-ET
Configuration Software. The system works fully automatically in normal operation. Further
operating elements are not available at the ICR890 System.
Parameter set on the SD memory card
The configured parameter values are saved as a parameter set in the internal EEPROM of
the ICR890 System and on the SD memory card of the ICD890 Camera (cloning). If the
camera needs replacing, the memory card allows convenient and rapid transfer of the
parameter set to a new device (also see
Chapter 7.3 Replacing a system or a component,
).
Note
To prevent data loss, the SD memory card should only be removed or inserted in a new
device when the system is switched off.
The card can be accessed from the rear of the camera and is located behind a cover on the
panel with the electrical connections.
Fig. 3-13:
SD memory card for parameter set
SD memory card
removed cover
Opening for insertion of
the SD memory card