Operating Instructions
Chapter
6
ICR890
Operation
8011325/0000/2006-10-24
©
SICK AG · Division Auto Ident · Germany · All rights reserved
81
6.3.1
Overview of the configuration procedure
•
Connect data interfaces of the PC and the ICR890 System/MSC800
•
Start the SOPAS-ET Configuration Software and create a new project file
•
Configure the scan assistant (activate PC communication)
•
Establish communication with the ICR890 System/MSC800
•
Accept current configuration of the ICR890 System/MSC800 in the project tree
•
Use the password “client“ to register at the system as an “authorized client“
•
Configure the ICR890 System/MSC800 for use
•
Activate the image output of the SOPAS-ET Configuration Software (“Image Viewer“) to
check the reading
•
If necessary, apply the diagnosis tools “Reading Diagnosis“ and “Event Monitor“
(online presentation/recording of the switching statuses of switching inputs and
outputs as well as data transfers to the host)
•
Load the optimized configuration into the ICR890 System and save permanently
•
Save the project file with the configuration data of the ICR890 System/MSC800 at the
PC
6.3.2
Establishing communication with the ICR890 System/MSC800
Prerequisite
The TCP-IP protocol at the PC has to be active to enable communication via TCP-IP.
Connecting data interfaces
¾
Interconnect the PC and the ICR890 System/MSC800 according to
.
s
Connection via:
At data interface:
Comment
MSC800
ETHERNET 1
(10/100 MBps)
Connect the PC (Ethernet interface), MSC800
(
ETHERNET 1
connection) and the ICR890 System (HOST ETHERNET connection) to
a joint switch using a patch cable no. 6030928 (10 m (32.8 ft)) or
no. 6029630 (3 m (9.84 ft)) for each connection.
MSC800 (optional)
AUX 1 or HOST 1
(RS 232)
Connect the PC via a 3-wire null modem cable no. 2014054 to the
9-pole D-Sub connector AUX 1 of the MSC800.
ICR890 System
HOST ETHERNET
(10/100 MBps)
Directly connect the PC (Ethernet interface) to the HOST ETHERNET
connection of the ICR890 System
via a crossover cable.
- or -
Use the patch cable (1:1) no. 6030928 (3 m (9.84 ft)) or no.
6029630 (10 m (32.8 ft)) when connecting via a hub.
ICR890 System (optional)
AUX or HOST
(RS 232)
Provide the cable no. 6028420 (open end) for connection to the PC
with a 9-pole D-Sub socket and, depending on the interface type,
configure it as a null modem cable.
(For wire colour assignment: see
, transmitter and
receiver signals are crossed, see
Connect the PC via the cable no. 6028420 to the AUX connection or
the ICR890 System
HOST.
Tab. 6-2: Connection between the PC with the SOPAS-ET Configuration Software and the ICR890 System/MSC800