MAINTENANCE AND REPAIR
9
89
8027513/V1-0/2022-03|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | MDA Vision
9.3.1
Replacing 3D snapshot Camera
Fig. 65: Replacing 3D snapshot camera
Legend
1
Mounting plate
2
Terminal blocks
3
Clamping screws
▸
Switch off the device using the main switch of the MDA Vision.
▸
Unscrew all connecting cables from the defective device.
▸
Unscrew and remove the clamping screws on both sides.
Fig. 66: Loosening and removing clamping screws
▸
Tilt the camera away from the front.
▸
Slide the camera upward and unhook it from the clamping blocks.
Fig. 67: Unhooking the camera from the clamping blocks
Removal