CHAPTER 1. OUTLINE OF THE PRODUCT
PN-T321/T322B
OUTLINE OF THE PRODUCT
1 – 6
2. PART NAMES AND FUNCTION
2 - 1. DISPLAY
■
FRONT VIEW
MEMO
n
Use a pointed object such as a pen tip to press the switches at
the operation panel.
REFERENCE CHART OF POWER LAMP LIGHTING STATUS
2
3
4
5
1
1
LCD panel
2
Power LED
3
Power switch
4
Input switch
5
Remote control sensor
Lighting Status
Status Description
Green lamp is lit.
In the power “ON” state
Green lamp is flashing.
In the input signal waiting mode (When DVI-D or D-SUB)
Orange lamp is lit.
In the power “OFF” state (Standby status=The power is turned off by the remote controller.)
If the Power switch is pressed when the display is in the input signal waiting mode (green lamp flashing), it also goes
into the standby status.
Lamp is flashing in
red
3
green
3
red
3
green
at 1 second intervals.
(Temperature
abnomaly)
The message “TEMPERATURE” blinks at 5-second intervals in the corner of the screen (Lower left corner at the fac-
tory default), and it indicates an abnormality in the internal temperature.
*
It operates only when “FUNCTION” - “TEMPERATURE ALERT” is set to “OSD&LED” or “LED”.
When it is “OFF”, it does not blink. (Factory default: “LED”)
*
Even when “FUNCTION” - “LED” is set to “OFF”, the setting of “TEMPERATURE ALERT” takes effect.
At the same time, the brightness is forcefully reduced by the internal processing of the LCD monitor.
If it is left in the above state and the internal temperature increases further, the monitor shuts off automatically. (Goes
into the standby mode.)
By cycling the main power or turning off and on the power by the remote controller, the screen can be restored to its original
state temporarily. However, it goes back to the standby status soon unless the cause of the temperature increase is removed.