CHAPTER 5. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-T321/T322B
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
5 – 7
9 - 4. RESET OF THE TEMPERATURE
WATCH SETTINGS
In the cases below, reset the settings by following the procedures.
n
When the previous temperature watch settings remain at the time of
replacing the PWB.
n
When the usage time has been reset at the time of replacing the
panel or the like.
MEMO
n
The temperature watch setting data contains a part that stores
the usage time of the display as basic information.
1 ) Press [Reset] button to execute the reset.
2 ) To confirm that the settings have been properly reset, press [Read]
button to read out the set values.
3 ) For the default settings, please see the followings.
DEFAULT THRESHOLD TEMPERATURE
PN-T321
PN-T322B
Installation Orientation
Landscape
installation
Portrait
installation
Brightness down temperature
(Level 5 of brightness)
58
57
Shutdown temperature
62
62
Installation Orientation
Landscape
installation
Portrait
installation
Brightness down temperature
(Level 5 of brightness)
58
58
Shutdown temperature
62
62