![SENSTAR Symphony 7.2 Series User Manual Download Page 78](http://html.mh-extra.com/html/senstar/symphony-7-2-series/symphony-7-2-series_user-manual_1244253078.webp)
Symphony Server
Face Recognition settings
Overview
Setting
Description
Analysis Resolution
Set the resolution for the camera on which Face Recognition is
active.
Analysis FPS
Set the frames per second for the camera on which Face
Recognition is active.
Face Confidence Threshold
Set how confident Face Recognition must be that objects are
faces before it tracks objects.
Template Quality Threshold
Set how clear objects must be before Face Recognition tracks
objects.
Max Turn
Set the horizontal angle (in degrees) from center where Face
Recognition does not track objects. The recommended value is 45
degrees or less. The maximum value is 70 degrees.
Max Tilt
Set the vertical angle (in degrees) from center where Face
Recognition does not track objects. The recommended value is 20
degrees or less. The maximum value is 45 degrees.
Processing mask
Setting
Description
Drawing Mode
Select whether the paintbrush marks areas in the processing
mask image to include (Analyze) or exclude (Ignore).
Senstar Symphony User Guide
78