Symphony Server
Setting
Description
Automatically Select Resolution
Based on Calibration
Select to automatically set the analysis resolution based on the
settings in the Calibration section.
Analysis FPS
Set the frames per second for the camera on which Indoor People
Tracking is active.
Simple Mode
Select whether to hide or display the advanced settings. Simple
mode is the default mode. Advanced mode is intended for system
integrators and technical support staff.
Processing Mask
Setting
Description
Drawing Mode
Select whether the paintbrush marks areas in the processing
mask image to include (Analyze) or exclude (Ignore).
Size
Select the size of the paintbrush that you use in the processing
mask image.
Counting Line
Setting
Description
Create
On the image, click and hold the left mouse button, move the
mouse to draw the new counting line, and release the left mouse
button.
Delete
Click a counting line to select it and press Delete.
Move
Hold the CTRL key, click and hold the left mouse button on the
counting line endpoint, and drag the endpoint to the
Add a connected counting line
Click and hold the left mouse button on the endpoint of an
existing counting line, move the mouse to draw the new counting
line, and release the left mouse button.
Change the counting direction
Click an arrow on the counting line to toggle counting for that
direction on and off.
Calibration
Setting
Description
Type
Select the type of calibration. Manual allows you to set the
camera position. Automatic allows the video analytic to set the
camera position and field of view. Uncalibrated runs the video
analytic without camera position and field of view information.
Zoom In
Click to make the calibration diagram larger.
Senstar Symphony User Guide
69